Dryer would stop heating after 5-10 minutes.
Unplug power. Remove the lint filter and remove the 2 screws under the lint cover lid. Use flathead screw driver to pop off the top of the dryer housing. The clips are located at the front two corners.Just wedge and lift up to unclip. Remove two hex head screws on each side disconnecting the side housing from the front housing. Disconnect the wiring harness at the front top right side if you are facing dryer. Lift up on the front housing to unclip the bottom of housing. Just lift up and pull housing face toward you at an angle. The circular dryer piece where clothes go into will be loose but still attached. It will sag down a little. Then on bottom left side unscrew two screws to remove the 2 coils. You will need a stubby phillips screw driver about 1.5" long and you will need to lift up on the dryer circular piece out of the way a little. Once you remove the crews, remove the clip holding the two coils. Remove the wiring from the coils. 1 coil has two leads and one has 3. Replace one at a time just in case your model is slightly different. Be sure to install the coil with the little knobby part up and in alignment for when you reinstall the clip/ bracket that holds it in place. Replace the coils and install the racket/ clip with 2 screws. Reinstall the wires. Reinstalling the front face of dryer housing is a little tricky because you have to slide the bottom back onto the clips while holding the circular dryer part up. Then push the front housing up against the circular piece so they are aligned and fit. While holding it, screw the two hex screws on each side. Then reconnect harness and snap the top housing back onto the front face housing clips. Reinstall the two screws at the lint trap. Reinstall the lint trap and plug back in. The dryer is now fixed if that was your problem. Its a fairly simply job once you start doing it. Good luck.
Parts Used:
M Series New Style Coil Kit
  • william from SAN DIEGO, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no flame on burner after initial ignite
I shut off the power supply (pulled plug) . Opened the front access door on bottom of dryer, The two coils sat on top of burner unit, with a plate and 2 Phillip head screws securing them. .I used a small set of pliers to pull the terminals off, then I used a short Phillip head screw driver due to the proximity of the dryer drum close by. The coils slide off, slide the new ones on, re secure the plate with screws, reconnect the terminals, plug in the power cord and away you are for a fraction of the cost.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Thomas from Muskegon, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas dryer would not ignite.
I removed two wires from the coil valves. Then I removed two screws from the bracket that holds the coil valves in place. I removed the faulty coil valves and replaced them with the new ones. Put the bracket back on and replaced the two screws and wires. It took almost 5 minutes. The dryer is like new once again.
Parts Used:
M Series New Style Coil Kit
  • William from Plainfield, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer was not heating
popped top up with flat screw-took out 4 screws (2 screws-1/4" nut driver - 2 phillips screws on bracket that holds coils in place) unplugged 2 wire lugs (1 three wire & 1 two wire) changed out bad coils screws back in-plugged wires back in -popped top back down .done
Parts Used:
M Series New Style Coil Kit
  • marlon from KINGMAN, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer not heating
replace two heating coils. Dryer working find.
Parts Used:
M Series New Style Coil Kit
  • Ramon from BROOKLYN, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flame wouldn't ignite.
I watched a video. The man speaking was Wayne from parts direct. He made the repair go so smoothly. I enjoyed watching him and I hope you include him in more videos. Had dryer apart and back together (after I had to take top back off, to re-attach the door switch, which I forgot. Had a senior moment!!) in 15 min.And working as good as new. Thank you Wayne. Have a nice day. Bryan
Parts Used:
M Series New Style Coil Kit
  • Bryan from YORK, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Everything works except no Heat
DISCONNECT THE POWER. (I got shocked a few times during the diagnoses stage). Remove the lint catcher. Pop the top of the dryer up (there are two plastic tabs along the front of the dryer. Remove the two screws for the lint catcher and open the top of the dryer. Loosen the screws between the side and front panels. Lift up on the front of the dryer to free it from the clips down below. Swing the front panel out of the way to avoid disconnecting the door-open-switch. Undo the two screws holding the bracket onto the gas burner regulator. Replace the coils. Reassemble in the reverse order. It was helpful to open the dryer door to help align the drum and front panels.
Parts Used:
M Series New Style Coil Kit
  • Benjamin from CRYSTAL LAKE, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Heat would quit working after a few minutes
Installed new coil, helped but have other issues that I'm troubleshooting.
Parts Used:
M Series New Style Coil Kit
  • Ron from CHESAPEAKE, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would not heat.
Diagnose that the circuit is functioning up to the igniter. This is done by removing the peep hole cover on the bottom front panel, turn the dryer on and watch for a glowing igniter. My dryer would still ignite the first time because the coils would not show an "open" until they heated up. So if you see the igniter glow it is most likely your coils are bad. Remove two screws from lint trap area on top of dryer. Pry up on top panel at the two clips. Panel is on hinges, so flip it out of the way or just brace it with something enough to keep it off the front panel. Remove the two bolts from inside top corners of the front panel. Use a small punch or screw driver to push in on the tab to release the doors electrical connector. Pull straight up on front panel to remove it from bottom clips. The gas valve is very easy to get to without removing the drum. If needed for inspection or cleaning, just pull back on the belt tensioner to remove the belt from the motor and then pull the drum out. Or just use a stubby phillips screw driver to remove the bracket from the top of the ignition coils. Use a very small flat head screw driver to lift the locking tab on each electrical connector while removing. Remove the coils and place new ones in very same position (note the tab or key way of the coils faces up and are defined in the bracket). Re-assemble all parts making sure connections are tight and drum is correctly mounted. Note: if you remove the drum, return the belt back, in a loop, through the tensioner. This part hurt my head for a moment because I did not pay attention. Also a good idea to vacuum the debris and lint while your in there! As always check to make sure the exhaust pipe is clear. Have fun!
Parts Used:
M Series New Style Coil Kit
  • Melissa from FOWLER, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would not heat
Followed directions from Youtube video
Parts Used:
M Series New Style Coil Kit
  • Michael from STOW, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The heat would go off after a few minutes
Removed the screws on the dryer vent and the back of the dryer top. Then I raised up the top panel and removed the screws that held the front panel on. I removed the front panel to access the coils. I replaced the coils and then the front and top panel and screws. All went well. The dryer is working properly now.
Parts Used:
M Series New Style Coil Kit
  • John from MUSKOGEE, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Wrench set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer not getting hot
Open top of dryer, then remove front. Coils on lower left. Unplug and replace coils. Vacuum loose lint from bottom of dryer. Replace front then top of dryer. Test run. All good !
Parts Used:
M Series New Style Coil Kit
  • jeff from SPARTA, NJ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer not heating( after replacing the high temp. thermostat
i removed the door and front panel then removed the two screws holding the coil bracket,disconnected the two wires on coils,set new coils in place and reversed the above process
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • james from HURON, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer not getting clothes dry
Dryer was getting hot at start of cycle and would drop out flame and then cycle flame every 45 sec to 1 min. Pulled of panel to observe this and thought it was a heat sensor problem. Went online and people were saying a coil could be bad. I took coils out and tested them and they tested good but I bought new ones anyway as I figured they were going out of range as they heated up, This proved correct as dryer works .
Parts Used:
M Series New Style Coil Kit
  • Dennis from LINDENHURST, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer not drying- gas valve coil resistance measured 'Open'.
Unplug dryer first! Remove toe panel with 1/4" nut driver on each lower corner. Gas assembly will be on the right immediately below right of drum. Use a short Phillips screwdriver to break loose two screws retaining hold-down plate on gas valve coils. I used an adjustable wrench to turn the screwdriver on screws which are not easy to apply torque to. Each coil will easily slip off stem. Disconnect catch on plug with very small flat tip screwdriver for each coil, then pull off connector. Ensure the 3-terminal coil goes to the front and the 2-terminal to the rear. Note aligning tips on coils which correspond to holes in hold down plate. Reassemble in reverse order except for toe panel. Plug in dryer and verify gas valve operation and flame presence. Replace toe panel.
Parts Used:
M Series New Style Coil Kit
  • Wayne from BAKERSFIELD, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 110694671
61 - 75 of 205