Water dispensed, but no ice.
6 of 7 people found this instruction helpful.
  • NANCY from VALLEY VIEW, OH
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
We have a side-by-side and the tutorial was different than what we have. Had trouble getting cover off, but finally repaired and WE HAVE ICE! Also took longer than expected.
Saved a lot!
Was this helpful?
Thank you for voting!
Icemaker Quit Making Ice
6 of 7 people found this instruction helpful.
  • JOSEPH from LINDENHURST, NY
  • A Bit Difficult
  • 15 - 30 mins
  • Screw drivers
Removed the two screws that hold flaping door. Removed the single screw that covers the connecting wires. Disconnected the wiring plug. I wiggled out the ice maker. Took off the motor cover. Swapped out one motor for the other. Reinstalled the icemaker in the resverse order of removal. Note the wiring plug in the freeze is very fro m. It makine s the reconnection differcult.
Was this helpful?
Thank you for voting!
Evaporator was clogged from no cleaning since new
8 of 14 people found this instruction helpful.
  • frederick from martinsville, IN
  • Easy
  • 1- 2 hours
  • Nutdriver
I heard the compressor running, it was very hot. I looked on the internet for that model and found where the overload was an answer for compressor not running. First order was from a different source and I was sent the wrong overload for this frig. I ordered from Partselect.com and was provided with phone support and was sent correct o verload. If I would have received the correct overload first, the time to repair would have been a 1/3 of the time. Thanks Partsselect.com.
Was this helpful?
Thank you for voting!
Stopped Making Ice
7 of 11 people found this instruction helpful.
  • John from Chandler, AZ
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Easy removal. Easy Plug and play install. Didn't even have to use the other wires. After install, put 4 oz of water into ice maker and wait....it didn't start making ice right away, but a couple hours later I heard the wonderful "ice dropping into the bin" sound. Worked great ever since.
Was this helpful?
Thank you for voting!
stop making ice
7 of 11 people found this instruction helpful.
  • Ricky from Philadelphia, PA
  • Easy
  • Less than 15 mins
  • Nutdriver
1.removed 3 nut screws-2 on top &1 on bottom.
2.unplug ref. from outlet.
3.unplug the wires from ice maker to ref.
4.remove ice maker
5.rinse new ice maker
6.plug ice maker to ref. using included wires
7.screw 2 top nut screws first then the bottom.
8.plug ref. back to outlet
9.made first ice in about 2-3 hours
Was this helpful?
Thank you for voting!
Refrigerator had shut down
7 of 11 people found this instruction helpful.
  • Ronald from Martinsville, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Was this helpful?
Thank you for voting!
Fridge would not defrost creating ice buildup and fridge would then get warm
7 of 11 people found this instruction helpful.
  • Susan from Madrid, NY
  • Really Easy
  • 15 - 30 mins
My brother came up and installed the part.
Was this helpful?
Thank you for voting!
Ice maker slowed down, then stopped producing
5 of 5 people found this instruction helpful.
  • Paul from Sharpsburg, GA
  • A Bit Difficult
  • 30 - 60 mins
  • Socket set, Wrench set
First pull out frig and unplug. Shut off water valve. I just had to remove two screws to disconnect unit from bottom rear corner of frig. Pull element out just a few inches and disconnect the plug that feeds it electric. Disconnect water hose and reattach to new unit. Reconnect electric plug and reinstall in back of frig, securing wit h two screws. I have an older appliance, so I had to jury rig a bit when reattaching new unit by drilling two new holes for mounting. Also, I had to buy a new water hose because the old part would not accept the standard female end of the hose to connect to. Home Depot has the standard icemaker hoses with two female ends. These two glitches would probably not apply to a newer appliance, but anyway, it's cranking out the ice just fine now! Sure I saved alot of money, even with the extra $10 investment for the hose.
Was this helpful?
Thank you for voting!
water leaked when the paddel was pushed
6 of 8 people found this instruction helpful.
  • Monica from EDMOND, OK
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this helpful?
Thank you for voting!
Ice maker stopped working. Thought it might be the timer. Actually teflon coating coming off.
5 of 5 people found this instruction helpful.
  • David from NASHUA, NH
  • Easy
  • 30 - 60 mins
  • Nutdriver
Removed the ice maker. Used a small mirror (wife's make up mirror) to find the screws. Inspected and found most teflon coating missing. Ordered new ice maker and installed. Works perfect.
Was this helpful?
Thank you for voting!
refrigerator not cooling properly
6 of 9 people found this instruction helpful.
  • Ernie from Windsor, CA
  • Really Easy
  • 1- 2 hours
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Was this helpful?
Thank you for voting!
wasn't making ice. The ice bin actually filled up with water.
5 of 6 people found this instruction helpful.
  • Bob from Middlefield, CT
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
Removed old valve first, found part # on it.
Entered part # into search box on computer.
It came up with the right replacement part the first time!!!
Ordered part, it came in sooner than I thought it would.
I attached the supply line, pushed in the plastic outlet hose, connected the power line, and attached it to the r efrigerator frame. We had a full container of ice the next morning.It couldn't of had been easier.
Was this helpful?
Thank you for voting!
Leakiong water from the freezer compartment into the lower refrigeration compartment
7 of 12 people found this instruction helpful.
  • Mark from indianapolis, IN
  • Really Easy
  • Less than 15 mins
  • Nutdriver
After unplugging the appliance, I unscrewed the screws in the bottom and the back of the freezer compartment and un-clipped the connector for the ice machine, which i do not have installed. I clipped the pink and brown wires and replace the switch with the new switch. unfortunately, the appliance is still dripping water from the freezer c ompartment. It worked for a couple of days then stopped working. Still looking for a true FIX.
Was this helpful?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
6 of 9 people found this instruction helpful.
  • Wayne from Arlington, TX
  • A Bit Difficult
  • Less than 15 mins
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causin g the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Was this helpful?
Thank you for voting!
broken kickplate
8 of 15 people found this instruction helpful.
  • Patricia from Ypsilanti, MI
  • Easy
  • Less than 15 mins
just snapped it on,
Was this helpful?
Thank you for voting!