no power to the ice maker
11 of 21 people found this instruction helpful.
  • Thomas from Indianapolis, IN
  • Really Easy
  • Less than 15 mins
  • Nutdriver
The wiring harness was a straightfoward plug in replacement after depressing the securing tabs, and did provide power to the icemaker. However, the icemaker would continually cycle, with the mold heater on at all times. I suspect this is what caused the thermal fuse to blow in the first place. Rather than spend more time replacing individ ual components, I eneded up replacing the full ice maker assy. The new ice maker works properly.
Was this helpful?
Thank you for voting!
Black flecks in ice
6 of 6 people found this instruction helpful.
  • Anthony from Billings, MT
  • A Bit Difficult
  • More than 2 hours
  • Nutdriver, Screw drivers
The lining of the ice mold (Whirlpool) started flecking off (black flecks in the ice cubes), so I decided to replace the mold.
Loosen the two 1/4 inch upper nuts and remove the lower nut to remove the ice maker from the freezer. The hardest part was getting it unplugged. I used a small blade screwdriver to release the catch on the c onnector and pull it out.
Remove the ice maker front cover. If you have a skinny enough phillips screw driver, there are two deep set screws through two holes on the lower portion of the control module (otherwise, remove the three screws on the controller, unlatch the shut-off arm from the control module, and separate the controller to access the mold screws). Unhook the shut-off wire from the end of the tray. Unscrew the two screws holding the mold and remove the mold.
Remove the plastic hardware from the old mold and install on the new mold.
Attach the new mold on to the control module.
WARNING WARNING WARNING!!! The mold I bought already had the alumilastic on it for the contact point to the thermostat. When I installed it and tightened the screws, the alumilastic was dried out, didn't squash down, and dented the bi-metal thermostat on the controller, ruining it. I had to buy a new thermostat. Be sure to check that the alumilastic is pliable. If not, take it off and buy some fresh to put on there.
Re-install the ice maker. It took a while to get the first batch of ice because the ice maker was at room temperature and I had the freezer door open for several minutes. So the freezer had to get cold and the ice maker had to chill down. Once everything got cold, it started making ice again.
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people found this instruction helpful.
  • Antonio from San Antonio, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
Icemaker Quit Making Ice
6 of 7 people found this instruction helpful.
  • JOSEPH from LINDENHURST, NY
  • A Bit Difficult
  • 15 - 30 mins
  • Screw drivers
Removed the two screws that hold flaping door. Removed the single screw that covers the connecting wires. Disconnected the wiring plug. I wiggled out the ice maker. Took off the motor cover. Swapped out one motor for the other. Reinstalled the icemaker in the resverse order of removal. Note the wiring plug in the freeze is very fro m. It makine s the reconnection differcult.
Was this helpful?
Thank you for voting!
No tempersture control, it was either onand freezing or off and hot.
7 of 10 people found this instruction helpful.
  • loy from Pahrump, NV
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
A simple job to remove the plastic cover held by two screws. Then one screw which held the old controller frame. Then remove two screws which held controller. Putting it back was just the reverse.
I did not have to adjust the new control position but with the wrench in the kit it would have been no trouble to do that either. ... Read more > The instructions were just fine and anyone with a little mechanical knowledge could do it
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people found this instruction helpful.
  • Peter from Herndon, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
Water dispensed, but no ice.
6 of 7 people found this instruction helpful.
  • NANCY from VALLEY VIEW, OH
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
We have a side-by-side and the tutorial was different than what we have. Had trouble getting cover off, but finally repaired and WE HAVE ICE! Also took longer than expected.
Saved a lot!
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people found this instruction helpful.
  • David from Choctaw, OK
  • Easy
  • 30 - 60 mins
  • Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this helpful?
Thank you for voting!
In the ice storm in bootheel of Mo the power spiked a few times before it went off. When power came back on, my frige wouldn't stay working. I would have to touch the thermostat to make it cycle back on. Found exact parts on line at partselect needed to repair the fridge. thanks guys!
6 of 8 people found this instruction helpful.
  • George from Gideon, MO
  • Easy
  • Less than 15 mins
  • Nutdriver
First I unplugged the appliance, then I took the two screws out that hold the cover over the temp. control knobs,then I removed the cover from the fan and thermocouple probe end. Then I unplugged the two hot wires from the thermostat,and then the ground wire. Then removed the two screws holding the thermostat in place and removed old ther mostat. Installed new thermostat following steps in reverse order.
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people found this instruction helpful.
  • Duncan from Metairie, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?
Thank you for voting!
Refrigerator had shut down
7 of 11 people found this instruction helpful.
  • Ronald from Martinsville, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Was this helpful?
Thank you for voting!
Had to bang on the Thermostat to get the compressor to kick in.
5 of 5 people found this instruction helpful.
  • Richard from O FALLON, MO
  • Really Easy
  • 15 - 30 mins
1.unplugged the refrigerator.and took off 2 knobs, and 2 screws to remove the cover from the back wall of the refrigerator.Next I unhooked 3 wires,and removed the mounting bracket by removing 1 screw. I had to use a file to slightly modify the bracket, since the thermostat was not the exact same model as the original,due to the age of the refrigerator.(40+years) I reassembled in the reverse order, and it works great
Was this helpful?
Thank you for voting!
water leaked when the paddel was pushed
6 of 8 people found this instruction helpful.
  • Monica from EDMOND, OK
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this helpful?
Thank you for voting!
Ice maker slowed down, then stopped producing
5 of 5 people found this instruction helpful.
  • Paul from Sharpsburg, GA
  • A Bit Difficult
  • 30 - 60 mins
  • Socket set, Wrench set
First pull out frig and unplug. Shut off water valve. I just had to remove two screws to disconnect unit from bottom rear corner of frig. Pull element out just a few inches and disconnect the plug that feeds it electric. Disconnect water hose and reattach to new unit. Reconnect electric plug and reinstall in back of frig, securing wit h two screws. I have an older appliance, so I had to jury rig a bit when reattaching new unit by drilling two new holes for mounting. Also, I had to buy a new water hose because the old part would not accept the standard female end of the hose to connect to. Home Depot has the standard icemaker hoses with two female ends. These two glitches would probably not apply to a newer appliance, but anyway, it's cranking out the ice just fine now! Sure I saved alot of money, even with the extra $10 investment for the hose.
Was this helpful?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
6 of 9 people found this instruction helpful.
  • Wayne from Arlington, TX
  • A Bit Difficult
  • Less than 15 mins
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causin g the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Was this helpful?