noisey circulating fan in the freezer
  • Lee from Arvada, CO
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Emptied the freezer. Removed the back panel. (six screws)Removed the fan cover.(4 screws) Unplugged the power. Unplugged three wires from the motor. (hot-neutral-ground)Removed the fan. (2 screws) Installed the new fan and centered for clearance. Reversed the prior instructions.
Was this helpful?
Thank you for voting!
no problems at at all
  • Eliseo from Pleasanton, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
removed rear wall panel took off old fan motor disconnected motor. Installed new grommets re-installed motor inserted new fan. Didn't have to trim fan re-connected wires and rear panel and reconnected power. no problems...
Was this helpful?
Thank you for voting!
Switch didn't work
  • Don from Laramie, WY
  • Easy
  • 15 - 30 mins
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Was this helpful?
Thank you for voting!
Heard a five second buzzing sound repeated 4 or 5 times per cycle coming from rear lower left compressor side.
  • Burton from Pecatonica, IL
  • Easy
  • 15 - 30 mins
  • Nutdriver
Removed the six screws holding the bottom access plate found at the rear of the refrigerator. This gives you easy access to the run capacitor that has a retaining clip. Remove the wire clip and pull out the capacitor (it has two quick disconnect terminals). Reverse the process using the new run capacitor to complete the repair.
Was this helpful?
Thank you for voting!
Repalce evaporator fan
  • William from Ledyard, CT
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The evaporator fan is located in the freezer behind the back wall. If you have the ice maker remove it first then remove the screws on the top of the panel. You will notice the side brackets for the top shelf will make it hard to remve the panal but by slitly binding the center the panal came right out. The fan is held in a bracke tha co mes right out. The wire unplu right from the fan so do not try to unplg the seal plug to the left side. Swap the fan with the new one useing the new rubber monts re-connect the wires and reasymble. Put the bottom of the back panal in first then work each side in past the shelf bracket binding the center slightly.
Was this helpful?
Thank you for voting!
rReally Noisy Fan
  • Robert from Sierra Vista, AZ
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
1. Unplug Refrigerator 2. Remove inside back freezer panel. (4 Screws) 3. Remove Duct Cover (3 Screws). 4. Cut electrical connections to fan. 5. Remove Old Fan motor (2 hex screws. 6. Install ground wire (was not one there previously). 7. Put slide-on electrical connectors on remaining 2 motor wires. (Were not any on original unit.) 8. R eplace Fan Motor (Don't forget the rubber vibration pads) 9. Reconnect electrical wires. 10. Press on plastic fan blade. 11. Plug in refrigerator to test install. It works. 12 Unplug refrigerator and replace ducting and back panel to freezer. Plug it back in. Voila, Quiet again.
Was this helpful?
Thank you for voting!
Evaporator motor squeal.
  • Steven from Hilliard, OH
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
After finding an almost obsolete part( thanks PartSelect!) the installation was rather easy. Remove the back panel of the freezer and vent with a screwdriver and a nut driver. Disconnect the three wires, green, white and red.Remove motor from mounting and replace with new motor. I had to make a slight adjustment to the ground wire on the new motor that required adjusting the position of the contact-no big deal. The motor fit perfectly. Popped fan on and assembled. 20 minutes max.
Was this helpful?
Thank you for voting!
Light switch which turns on the lights when the door opens went out
  • Dennis from Lawrenceville, GA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
This is an easy fix, simply remove and replace. What I was impressed with is that a how to video was provided along with my part. I wish all manufactures would offer this, the video was easy to understand and you had a good view of the operation. Thanks, a job well done.
Was this helpful?
Thank you for voting!
Noisy fan
  • Harry from Cincinnati, OH
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Unplug the refrigerator. Remove the rear shelf supports by lifting them straight up. No tools required. Remove the screws holding the rear cover of the freezer. Use a nut driver to remove the 4 screws holding the fan housing. Unplug the wiring harness, then remove the fan and install the new one. Remount the housing, plug in the har ness replace the rear cover, install the shelf supports and plug in the refrigerator. It was 30 minutes start to finish, which includes the time to gather the tools, unload and reload the freezer, and putting the tolls away!
Was this helpful?
Thank you for voting!
light switch sticking
  • Paula from Rush, NY
  • Easy
  • Less than 15 mins
  • Pliers, Screw drivers
I watched the video and thought "I can do this". Made some notes and then proceeded to remove the old switch and replace with the new one. Thank you.
Was this helpful?
Thank you for voting!
Loud noise from freezer when running
  • Joseph from Cottsge Grove, WI
  • Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
Pulled the electric plug! Removed the freezer shelf and the rear shelf supports by pulling straight up. Swung rear panel out of the way after taking out the two phillips head screws at the top. Removed the plastic deflector grill to which the motor is attached with a nut driver. Removed motor from grill and disconnected wire prongs (pul l off). Attach new motor. Only issue - the ground prong has been moved to the front of the motor so the wire just reaches and has to be gently bent back so the fan blade clears it. Reattach deflector grill. Push on fan blade, but not too far to hit wire. Reassemble the rest in reverse order.
Was this helpful?
Thank you for voting!
Refrigerator cooling fails to come back on after defrost cycle.
  • Donald from Seattle, WA
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Since the defrost timer turns the cooling functions on and off for each defrost cycle if seemed the most likely problem. That was confirmed by manually advancing the timer with a screw driver and the cooling functions would resume and run until the next defrost cycle (every 8 hours or so). The repair itself was to swap out the timer whi ch took five minutes with a #2 phillips screw driver and a 1/4" nut driver. Once the timer was removed from the cover plate there's a simple plug-in connector to remove from the old and plug into the new timer. Two machine screws hold the timer in place behind the cover plate. Be sure switch the power off on the compressor cabinet before removing the cover plate.
Was this helpful?
Thank you for voting!
Light switch in the refrigerator was faulty from the first day we installed the fridge.
  • Mary from Wasilla, AK
  • Easy
  • Less than 15 mins
  • Screw drivers
I had ordered some other parts for something entirely different off your website and service was great. So after almost ten years of a dark refrigerator, because of a defective switch, I decided to see if you had the part to fix it... You did and the part got here in 3 days. I had a working light switch and all the light in the world whe re my husband needed it most (in the fridge). It took me at the most ten minutes to replace the part. All is well now and I have a happy husband who can find the leftovers just fine. Thanks for your great service!
Was this helpful?
Thank you for voting!
Light did not come on (bad bulb!) on TC18KL
  • Louis from Beloit, WI
  • A Bit Difficult
  • Less than 15 mins
I have never before seen a bulb with the filament intact not light. If the bulb's filament seems intact, screw the bulb into a known working lamp and see if it lights. When screwing it back into the socket in the fridge, it takes a bit of extra effort to fully seat (until it does, it won't light!). For replacing the switch, I unplugged th e unit, used a paint scraper and worked it under the switch bezel from the right side. A bit of moxie, and the switch came out. The replacement switch had a different spade contact spacing than the original. I used a pair of scissors to cut the rubber bridge between the two switch wire connectors so I could connect to the new switch. In the end, it turned out to be the bulb. NOTE: The Model TC18KL is _not_ listed! What I finally found that the number "P7803211WL" on the sticker is actually a manufacturing code. Found this out by searching, and Sears' part search came up with matches.
Was this helpful?
Thank you for voting!
Refrigerator stop cooling
  • Ba from Van Nuys, CA
  • Really Easy
  • Less than 15 mins
I did remove the run capacitor of the starthing kit of compressor and another one new. It work fine.
Was this helpful?