There was no light on in refrig area
12 of 19 people found this instruction helpful.
  • Lori from Chuluota, FL
  • Easy
  • Less than 15 mins
  • Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
The refrigerator leaked water every time the ice maker filled.
11 of 16 people found this instruction helpful.
  • Robert E. from Darien, IL
  • A Bit Difficult
  • Less than 15 mins
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!
Was this helpful?
Thank you for voting!
No water in icemaker tray.
9 of 10 people found this instruction helpful.
  • Robert from Myrtle Beach, SC
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Confirmed that the solenoid controlled water valve (Part # PS358631) between the water source and the back of ice maker was defective. I did this by removing the valve and plastic hose from the back of the refrigerator and pointed the end that went into the icemaker towards the sink. I applied 110 volts to the valve and noted that no wate r was getting through. Replacing the valve was a snap.
Was this helpful?
Thank you for voting!
ice maker was leaking water
13 of 22 people found this instruction helpful.
  • Sandra from Temecula, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Parts went right into place as the pictures showed and was working again in about 30 minutes. The only thing that wasn't working was the ice took forever to make, but solved that problem by turning up the temp in the freezer.
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people found this instruction helpful.
  • George from Glenwood, MN
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Was this helpful?
Thank you for voting!
ice maker, intermittent hollow cubes, then no ice
9 of 11 people found this instruction helpful.
  • paul from madison, WI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Wrench (Adjustable)
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker ha s been working flawlessly since the repair.
Was this helpful?
Thank you for voting!
tube got cut and it leaked
9 of 11 people found this instruction helpful.
  • Robert G. from Kalkaska, MI
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
first I turned off the water supply then I removed screw that was holding the nozzle and pulled out the tube then I pried out the face plate by prying from the bottom with a thin screw driver then I unpluged the wire harness so I could access the black tube guide that the white tube was housed in before it was cut I pushed the new white tube down threw the black tube and out the bottom hinge I replaced the nozzle screw plugged the harness back in replaced the face plate went to the bottom and connected the tube to the other half replaced the bottom molding and turned on the water
Was this helpful?
Thank you for voting!
Chirping sound coming from the freezer-old gasket on food door causing air leakage r
11 of 18 people found this instruction helpful.
  • JAMES from WAUPACA, WI
  • A Bit Difficult
  • More than 2 hours
  • Nutdriver, Screw drivers
Removed shelving,ice maker & other air deverters to get at fan motor. Disconnected power, then removed motor by removing screws holding motor assembly in place. Push fan blade on to motor reconnect wiring.
Chirping stopped and ice cream is now rock hard.

Food door gasket was more time consuming than hard. Loosen old gasket screws with not driver. Gasket is then easily removed. Reinstall gasket, but keep retaining strips loose so you can adjust gasket for a correct fit.
Was this helpful?
Thank you for voting!
Our ice maker did not work.
10 of 15 people found this instruction helpful.
  • Jay from Flower Mound, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Socket set
I turned off the water supply and disconnected the power. Then I removed the back cover plate and the two water lines. Fortunately the water lines are a different size so it is not confusing which line goes on each outlet. Then I loosened the two screws that fasten the valve assembly. It requires a nut driver with a flexible drive or a 1/4" socket set with a "U" joint. We were then able to disconnect the third water line on the back side of the valve assembly. I then reversed the sequence to install the new valve. The only difficulty is getting the screws started on the valve assembly.
The trouble shooting guide in the Kitchen-aid user manual is totally inadequate. I bought and replaced the whole icemaker unit when all I needed was the valve.
Was this helpful?
Thank you for voting!
Refrigerator stopped cooling. Would restart when thermostat was tapped, but would stop again within minutes.
8 of 9 people found this instruction helpful.
  • Charles from Chatsworth, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Instructions were simple and clear. Removed knob, snapped off plastic control panel. Then removed five 1/4" head sheetmetal screws to remove metal bracket holding thermostat. Two more 1/4" head screws held the thermostat to the bracket. Then pulled off the three fast-on electrical connections and pulled the thermostat and thermocouple tube out. Reversed the process to install new thermostat. My 33 year old garage refrigerator now works perfectly again! NOTE: searching for "thermostat" on the site didn't work.. It's called a "cold control thermostat" for some reason. That's redundant; other than cold, why would a themostat be in a refigerator, for heaven's sakes!?
Was this helpful?
Thank you for voting!
ice maker leaking or overflowing into ice bend
9 of 13 people found this instruction helpful.
  • LARRY from DYER, TN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Wrench set
first bought new ice maker installed it-didn`t fix the problem. next bought fill tube kit and dual outlet vale -installed those ice maker works GREAT no leaks -no ice froze together in bend. thanks for the help GUYS.
Was this helpful?
Thank you for voting!
The fan quit
11 of 19 people found this instruction helpful.
  • donn from Ranier, MN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I took the old one out and put the new one in. EASY!
Was this helpful?
Thank you for voting!
35 year old water tube became brittle and cracked; leaking water
8 of 10 people found this instruction helpful.
  • Melvin from OPELIKA, AL
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Was this helpful?
Thank you for voting!
Ice getting stuck, and water flowing over everything
7 of 7 people found this instruction helpful.
  • Randal from Wakefield, RI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The on-line video and the hard-copy instructions with the replacement part made it very easy. Just loosened the 2 upper screws and took out the bottom one. Eased the ice maker out a bit and disconnected the plug at the back (power was off). Checked the replacement part had exactly the same wiring harness - it did. Fitted the bail arm from the old one. So simply did the same process in reverse. So 15-20 minutes after I started, the job was compelete. It takes a while for ice to start coming, but it did, and after 24 hours I threw out the ice and started again to make sure the ice came from fresh water.
Was this helpful?
Thank you for voting!
Icemaker not working
7 of 8 people found this instruction helpful.
  • Hal from Virginia Beach, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Wrench (Adjustable)
Started the replacement of the existing dual outlet valve by removing cardboard covering the lower back of the refrigerator exposing the outlet valve. Closed the water supply valve at the wall. Removed the hose bibb water supply connection on the outlet valve by hand as it is only hand-tight. I used a small plastic container to catch the minimal amount of water left in the copper line. I removed the electrical connection on each solenoid valve (one for the in-door water supply and one for the icemaker supply). I removed the plastic supply lines from the outlet valve. I removed the screws on the bracket attaching the dual outlet valve to the refrigerator vertical rail. I reconnected the electrical connectors to the valve. I reattached the plastic supply lines to the valve, but did not tighten them fully at this point. I secured the bracket on the new valve to the existing screwholes on the refrigerator rail. The new outlet valve does not have a hose bibb connector, it has a compression fitting for the supply. I reused the existing copper supply line from the wall angle-stop valve to reconnect to the new outlet valve. (It would have been best to have cut the copper line and used a new furrel on the copper line). Note that the supply line now comes into the outlet valve from the top, not the rear as on the old valve, so now the dual outlet valve sticks out beyond the frame of the refrigerator. I tightened the nuts on the plastic supply lines on the valve. I had to cut the cardboard cover around the new outlet valve. Resecured the cardboard cover to the back of the frig. Checked for leaks, turned the icemaker on by lowering the shutoff arm, and after a few moments, the outlet valve opened, water flowed into the icemaker, and all is well.