Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water in icemaker tray.
Confirmed that the solenoid controlled water valve (Part # PS358631) between the water source and the back of ice maker was defective. I did this by removing the valve and plastic hose from the back of the refrigerator and pointed the end that went into the icemaker towards the sink. I applied 110 volts to the valve and noted that no water was getting through. Replacing the valve was a snap.
Parts Used:
Single Outlet Water Valve Kit
  • Robert from Myrtle Beach, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker, intermittent hollow cubes, then no ice
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker has been working flawlessly since the repair.
Parts Used:
Single Outlet Water Valve Kit
  • paul from madison, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan had stopped-freezer not performing etc.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Parts Used:
Condenser Fan Motor Kit
  • George from Glenwood, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling. Would restart when thermostat was tapped, but would stop again within minutes.
Instructions were simple and clear. Removed knob, snapped off plastic control panel. Then removed five 1/4" head sheetmetal screws to remove metal bracket holding thermostat. Two more 1/4" head screws held the thermostat to the bracket. Then pulled off the three fast-on electrical connections and pulled the thermostat and thermocouple tube out. Reversed the process to install new thermostat. My 33 year old garage refrigerator now works perfectly again! NOTE: searching for "thermostat" on the site didn't work.. It's called a "cold control thermostat" for some reason. That's redundant; other than cold, why would a themostat be in a refigerator, for heaven's sakes!?
Parts Used:
Cold Control Thermostat
  • Charles from Chatsworth, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
35 year old water tube became brittle and cracked; leaking water
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Parts Used:
Water Tube Kit
  • Melvin from OPELIKA, AL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The fan quit
I took the old one out and put the new one in. EASY!
Parts Used:
Evaporator Fan Motor Kit
  • donn from Ranier, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
11 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice getting stuck, and water flowing over everything
The on-line video and the hard-copy instructions with the replacement part made it very easy. Just loosened the 2 upper screws and took out the bottom one. Eased the ice maker out a bit and disconnected the plug at the back (power was off). Checked the replacement part had exactly the same wiring harness - it did. Fitted the bail arm from the old one. So simply did the same process in reverse. So 15-20 minutes after I started, the job was compelete. It takes a while for ice to start coming, but it did, and after 24 hours I threw out the ice and started again to make sure the ice came from fresh water.
Parts Used:
Replacement Ice Maker
  • Randal from Wakefield, RI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator would freeze up and stop cooling, I would turn off defrost over a 24 hour period by leaving the freezer door open. Then turn it back on and it would cool like crazy for about a week and then it would freeze up agian. This went on for about a month then I knwe the problem was in the defro
The first thing to do was determine what part of the defrost circuit was bad. (it could have been the defrost timer assembly or the defrost heater or a bad wire in the circuit). To do this I took the cover off of the refrigerator temp control to see the timer. Taking a large screw driver I rotated the timer (clockwise) until I heard the compressor cut off. Then I placed a mark on the timer to note its location and waited to see if the mark moved( this indicated the motor was running). After 20 minutes the compressor kicked back on and the timer had rotated, this told me the timer was at least rotating. The next step was to see if there was voltage going to the defrost heater around the freezer evaporation coil. (The heater is what melts the frost of the evaporation (cooling) coils
This requires the removal of all the shelves, ice maker, and all the covers in the freezer section to expose the evaporation coil.
The defrost heater wraps around the outside edges of the evaporation coil. The heater is suppose to come on for 20 minutes every 8 hours to keep the evaporation coil from becoming covered with frost which will prevent the air from circulating into the refrigerator section.
I found where the heater leads plug into the back wall of the freezer and with the power on and in the defrost cycle (turn or index the timer around with the large screw driver until the compressor cuts off again). Carefully read across these two heater leads and check for 120 VAC. Noting there was 120vac across these two leads I then turned the refrigerator off and unplugged the refrigerator from the wall.
Now with the Volt Meter set to the Ohms setting I unplugged the two heater leads with the needle nose pliers and read the ohm value across the two wire leads of the heater element. (I got lucky and found a schematic folded up and stuck just behind the front grill at the bottom of the freezer). The schematic told me the ohm value should have been 22 ohms. However, my value was 0 ohms this told me the heater had an open circuit (it had a broken wire inside the heater element). I located the correct part using the model # on the Part Select website and ordered the defrost heater element for my model refrigerator. I received the part in three days.
Now for the fun part, of removing and installing the new element.
This is not brain surgery but … it is not for the faint at heart either, you must be able to work in tight areas and be agile enough to sit on the floor while reaching the back of the freezer and be patient and deliberate with your moves. (kind of like playing the Milton Bradley game “Operation” as a kid)
Next step is to remove the two top screws holding the evaporation coil to the back of the freezer, then remove the cover to expose the refrigerant lines inside the freezer, remove the two foam side supports holding the coil centered in the back of the freezer and then VERY carefully lift the evaporation coil straight up to un- hook it from the bottom clips which hold the bottom of the coil stationary. Then gently remove the two aluminum side plates from the coil by bending the tabs that hook these plates to the curved refrigerant coils they are hooked around. With the side plates removed then carefully un- hook the 4 clips which hold the heater in place around the evaporation coil. Using a pair of needle nose pliers unplug the heater leads from the back wall contact point (Remember to be sure and unplug refrigerator before doing this) At this point VERY carefully lift up slightly and gently pull the bottom of the coil out (trying to keep the top of the coil at the same elevation and parallel to the back wall pull the bottom out to a point where the heater element can be slid down and out of the evaporation coil as it is basically woven thru the coil assembly to efficiently defrost the coil.
Once the heater is carefully slipped down and out of the evaporation coil, replace the heater element with the new one by feeding the wires bac
Parts Used:
Heater
  • Charles from Dripping Springs, TX
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Chirping sound coming from the freezer-old gasket on food door causing air leakage r
Removed shelving,ice maker & other air deverters to get at fan motor. Disconnected power, then removed motor by removing screws holding motor assembly in place. Push fan blade on to motor reconnect wiring.
Chirping stopped and ice cream is now rock hard.

Food door gasket was more time consuming than hard. Loosen old gasket screws with not driver. Gasket is then easily removed. Reinstall gasket, but keep retaining strips loose so you can adjust gasket for a correct fit.
Parts Used:
Evaporator Fan Motor Kit Fresh Food Door Gasket
  • JAMES from WAUPACA, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working in fridge
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Parts Used:
Refrigerator Door Switch
  • Michael from East Meadow, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water pump for ice maker would not shut off
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires...) Then I put the new valve in, put the cover back on the refridgerator and was done. total time 15 minutes. My wife says I'm the man.
Parts Used:
Single Outlet Water Valve Kit
  • Lawrence from Clio, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Parts Used:
Condenser Fan Motor Kit
  • Peter from Herndon, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
6 of 7 people found this instruction helpful.