- Home
- 10652214101
- Instructions
10652214101 Kenmore Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
ice dispenser broken
17 of 26 people
found this instruction helpful.
-
sandra from mechanicsville, VA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
ridiculous how a tiny plastic broken part required a full motor assembly replacement. that being said, i went online, found this website and easily identified the part i needed to order. i was impressed when it arrived within a couple of days. removing the old motor and replacing the new was a piece of cake...and i am NOT mechanically i
... Read more
nclined,
Read less
Was this helpful?
Thank you for voting!
compressor quit working
13 of 14 people
found this instruction helpful.
-
Harry and Janet from Austin, TX
- Really Easy
- 15 - 30 mins
-
Nutdriver
Really simple clear instructions with photos. With this the repair was quick and easy simply remove the bad relay and replace with the correct one. Great delivery time with terrific instructions.
Was this helpful?
Thank you for voting!
burned out Evaporator Fan Motor
16 of 23 people
found this instruction helpful.
-
Robert from Surprise, AZ
- Really Easy
- 15 - 30 mins
-
Screw drivers
simply removed wires from the old motor and gently lifted it out by by the metal clips - put the old bracket on the new motor, snapped on the new fan, replaced the wires, reinstalled the shield. All done in about 15 min.
Other Parts Used:
Was this helpful?
Thank you for voting!
The freezer wouldn't freeze and the refrigerator wouldn't refrigerate.
13 of 15 people
found this instruction helpful.
-
Leandro from Baldwin Park, CA
- Easy
- Less than 15 mins
-
Screw drivers
Same as everybody else on this post. Real easy. Actually, I just wish I would have done it sooner.
Was this helpful?
Thank you for voting!
I had frost build-up in the freezer.
15 of 21 people
found this instruction helpful.
-
David from Arnold, ME
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Was this helpful?
Thank you for voting!
Refrigerator quit cooling at all.
16 of 24 people
found this instruction helpful.
-
Eddie from Ocean Springs, MS
- Really Easy
- Less than 15 mins
-
Nutdriver
I removed the cover for the lower part of the refrigerator to inspect the wiring and motor. I removed the switch and removed the wiring from it. The wiring just plugs in. When the new switch arrived, I just reinstalled it to the side of the motor and the refrigerator has been working fine ever since.
Was this helpful?
Thank you for voting!
Broken cup water fill on ice maker
13 of 15 people
found this instruction helpful.
-
Matthew from Aurora, CO
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.
Thanks,
Matt
Thanks,
Matt
Was this helpful?
Thank you for voting!
Refrigerator quit refrigerating
15 of 21 people
found this instruction helpful.
-
William from Hudson, FL
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Read less
Was this helpful?
Thank you for voting!
compressor not running
14 of 19 people
found this instruction helpful.
-
james from islamorada, FL
- Really Easy
- Less than 15 mins
-
Screw drivers
found power up to current relay but not to compressor. removed the old current relay and installed the new relay and the compressor started running and the refrigerator works fine now.
Was this helpful?
Thank you for voting!
Auger drum broke
15 of 22 people
found this instruction helpful.
-
Michael from Deer Park, TX
- Really Easy
- Less than 15 mins
-
Nutdriver, Wrench (Adjustable)
Very easy. Your online video was agreat help.
Was this helpful?
Thank you for voting!
Rattling noise in beind freezer compartment
14 of 19 people
found this instruction helpful.
-
Herman from Cottonwood, AZ
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
remove shelves in freezer compartment incl.holders(slide up to remove)
Remove lamp/shield
Remove panel (six phillips screws)
disconnect motor
pull off fan blade
squeeze bracket holding motor to remove
remove motor.
Re-assemble (in reverse)
Remove lamp/shield
Remove panel (six phillips screws)
disconnect motor
pull off fan blade
squeeze bracket holding motor to remove
remove motor.
Re-assemble (in reverse)
Other Parts Used:
Was this helpful?
Thank you for voting!
Suspected fan failure
12 of 14 people
found this instruction helpful.
-
Don from Oregon City, OR
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
I pulled the refer from the wall, disconnected the power and removed the cardboard cover at the base. Using a vacuum and compressed air, I cleaned it thoroughly.
I used a screwdriver to lift the locking tab on the 3-wire connector and removed it. The best way to get the three bolts off was with a 1/4" drive ratchet and go to the std ... Read more nutdriver handle when they were loose. The fan came out carefully with the blade. I removed the blade nut with flat nosed pliers, cleaned it and placed it on the new motor. I replaced the motor and installed the screws. On a do-over I would install onew screw in each hole at least halfway to get the threads started/ threaded. After that the connector slipped in and I spun the blade to check for interference. The blades can be slightly bent, but use of nut tension can also slightly adjust fan alignment as it's tight to the housing.
That's it
I used a screwdriver to lift the locking tab on the 3-wire connector and removed it. The best way to get the three bolts off was with a 1/4" drive ratchet and go to the std ... Read more nutdriver handle when they were loose. The fan came out carefully with the blade. I removed the blade nut with flat nosed pliers, cleaned it and placed it on the new motor. I replaced the motor and installed the screws. On a do-over I would install onew screw in each hole at least halfway to get the threads started/ threaded. After that the connector slipped in and I spun the blade to check for interference. The blades can be slightly bent, but use of nut tension can also slightly adjust fan alignment as it's tight to the housing.
That's it
Read less
Was this helpful?
Thank you for voting!
Water would not come out of the dispenser.
11 of 11 people
found this instruction helpful.
-
Ralph from Saint Petersburg, FL
- Easy
- 15 - 30 mins
-
Screw drivers
Removed catch tray and then removed two screws that are underneath. I left the control panel hanging from its wires, then removed the two screws from the control bracket.
A word of caution before next step: You need to remove the two micro switches on the left and right. While trying to remove one, it split apart and the pieces fell ... Read more out. I was able to put it back together and it worked fine. So be careful with the micro switches.
Continue tranferring wires and switches to the new bracket and reassemble in the opposite order.
An easy repair.
A word of caution before next step: You need to remove the two micro switches on the left and right. While trying to remove one, it split apart and the pieces fell ... Read more out. I was able to put it back together and it worked fine. So be careful with the micro switches.
Continue tranferring wires and switches to the new bracket and reassemble in the opposite order.
An easy repair.
Read less
Was this helpful?
Thank you for voting!
Noise coming from defrost timer
12 of 14 people
found this instruction helpful.
-
Thomas from Pottstown, PA
- Really Easy
- 15 - 30 mins
-
Nutdriver
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in
... Read more
the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Read less
Was this helpful?
Thank you for voting!
The in-door water dispenser stopped working but the ice continued to work.
13 of 17 people
found this instruction helpful.
-
Roger from MOUNTAIN HOME, AR
- Really Easy
- 15 - 30 mins
-
Nutdriver, Wrench set
I first had to identify the faulty part. I ohms checked the micro switch in the door. It was fine. I traced the wiring to the inlet valve at the bottom of the rear of the unit. I checked the voltage to the solenoids and it was good. After checking the schematics on the Whirlpool website, I determined the only possible faulty part was the
... Read more
inlet valve. I found the correct part here on PartSelect and ordered it. When the part arrived I changed out inlet valves by turning off the water supply, unplugging the refrigerator, removing the two inlet valve mounting screws, and disconnecting the wire terminals. The inlet water line was a 1/2" compression nut and the water and ice outlets were hand turn compression nuts. I reversed the removal steps to install the new valve, turned the water on, checked for leaks, plugged in the refrigerator, and the new valve worked perfectly. The feeling of accomplishing a DIY project was only topped by a happy wife who really didn't want to spend the money on a new fridge!
Read less
Was this helpful?
Thank you for voting!