MVH330W (P1307907M) Amana Microwave - Overview
Sections of the MVH330W
[Viewing 4 of 4]Keep searches simple, eg. "belt" or "pump".
Light Bulb - 40W
PartSelect #: PS2376034
Manufacturer #: 8206232A
This 40w light bulb is a replacement bulb constructed of glass and metal. It is an easy-to-install electrical part which produces 40w of light. If the bulb won't light up then it may be broken and sho...
$9.85
In Stock
Ceramic Fuse - 20 amp
PartSelect #: PS11747931
Manufacturer #: WPM0805101
This ceramic microwave fuse is just over an inch long. It is white in the center, while each end is made of metal. This is a twenty amp fuse.
$14.95
In Stock
Door Interlock Switch Kit
PartSelect #: PS373050
Manufacturer #: 4392027
This kit contains 2 switches - 15 Amp - 125/250 Volt with 3/16" terminals.
$138.14
Special Order
Microwave Light Bulb - 40W
PartSelect #: PS2172588
Manufacturer #: R0713676
Sold individually.
No Longer Available
Microwave Door Interlock Switch
PartSelect #: PS11742843
Manufacturer #: WP56001036
$69.25
Special Order
Door Handle
PartSelect #: PS2172561
Manufacturer #: R0713642
This white door handle is twelve inches long.
No Longer Available
Rack Support
PartSelect #: PS2195826
Manufacturer #: Y05200084
Sold Individually.
No Longer Available
Common Symptoms of the MVH330W
[Viewing 3 of 3]Won’t turn on
Fixed by
these parts
these parts
Show All
No heat
Fixed by
these parts
these parts
Show All
Doesn’t shut off
Fixed by
these parts
these parts
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
light bult needed to be replaced
The nightmare was that this microwave is installed under the cabinet....in order to get to the light bulb I had to pull out my stove then squeeze into the space between the stove and counter....my old microwave light bult was much easier to change.....Shame on Whirlpool for making this so difficult.....must be a better way to cover the light bulb so that we do not need a screwdriver to remove the door to get to the light bulb
Parts Used:
-
Deborah from Millersville, MD
-
Difficulty Level:Difficult
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
222 of 329 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bulb "burnt out"
Removed 1 screw, removed "burnt out" bulb and replaced it with new bulb.
Parts Used:
-
Joseph from Pembroke, MA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
98 of 164 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave worked intermittently depending on how door was closed
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and also took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
Parts Used:
-
Robert from Bainbridge Island, WA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
67 of 85 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!