MS-124ZK LG Microwave - Overview

Diagrams for MS-124ZK

See every part. Know exactly what you need.

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Turntable Assembly – Part Number: 5889W2A014D
$32.95
In Stock
Turntable Assembly
★★★★★
★★★★★
(1)
Part #5889W2A014D
This turntable assembly helps ensure even heating by smoothly rotating food during operation. The complete assembly provides stable support and consistent motion, contributing to improved cooking results and reliable performance.
Magnetron – Part Number: 6324W1A001L
$120.07
In Stock
Magnetron
Part #6324W1A001L
This part is used to generate microwave energy/heat.
Lamp,Incandescent – Part Number: 6912W3B002L
$27.95
In Stock
Lamp,Incandescent
Part #6912W3B002L

Common Symptoms of the MS-124ZK

How this model fails, and the parts that fix it.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Magnitron failed
8 of 13 people found this instruction helpful.
  • Joseph from WILTON, NH
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
Over the stove microwave installed in top cabinet row.
1. Unplug device.
2. Two people to remove from wall/cabinet (remove two, large, top mounting screws and rotate entire microwave down and off the wall mount). Should be some wood spacers between top of device and bottom of cabinet.
3. Remove screws from sheet metal cover .
4. Remove one screw holding blowers in place and rotate out of the way, in order to gain access to 2 of 5 screws that hold the magnetron in place.
5. Unplug magnetron and remove the 5 screws.
6. Drop in new magnetron and re-assemble microwave in reverse order (steps 5-3).
7. Two people restore micro to wall/cabinet. Replace wood spacers, re-install two, large mounting screws (finger-tight). Test device. Secure the two large screws.
Was this helpful?
Thank you for voting!
Would not heat and made a buzzing or popping sound
4 of 7 people found this instruction helpful.
  • Thomas from NEWARK, DE
  • Easy
  • 15 - 30 mins
  • Screw drivers
Unplug the microwave. Remove the Philips head and safety Torx head screws along the bottom of the sides and rear of the microwave which hold the black cover on. Lift the cover up at the rear and slide it backwards to disengage the tabs on the front top. Remove the cover. Discharge the capacitor by shorting the terminals to each other and then ground. Do this with a well insulated object and be aware there may be a pop when you do this. Keep hands, etc. on the insulated part of the object (screwdriver handle, etc). There's a lot of stored energy in that capacitor. I'd advise first checking the diode to make sure its not bad. Replace it if it is. The Magnatron is held in with a couple of screws on the top and sides. Unplug the connector and remove the screws. Remove the Magnatron. Installation is the reverse of removal.
Was this helpful?
Thank you for voting!
Unit would not heat
1 person found this instruction helpful.
  • william from LA VERNE, CA
  • Easy
  • 30 - 60 mins
  • Pliers, Socket set, Wrench (Adjustable)
Used a Motor cycle Jack to remove both unites combined. Removed side panels exposing internal working parts. Removed nonworking Magnetron and replaced it with new Magnetron. The process was completed in about 1 hour.
Was this helpful?
Thank you for voting!