Lynn
December 7, 2019
What does the letter code " d" mean when the microwave has shut down
For model number MMV5000BDQ
Hello Lynn,
Thank you for your question. Problems such as bad interlock switches or a misaligned door are common culprits for microwaves that stop working. When these problems occur, they can cause a fuse to blow, stopping your appliance dead in its tracks. We suggest replacing the fuse under part PS2052604 for your model to fix the issue. Hope this helps!
I looked up the #1 reason for no heat for my microwave on the site , and using my model number found that 92% of the time it was the Black Sleeve Diode. Ordered the $15 part, and installed it within 30 minutes. Most of the time was used for removing the built in microwave and removing the cover. Replaced the diode by finding it on the diagram that I printed from this site (free). Very relieved that we don't need to have our custom cabinetry re-sized to accommodate a new microwave. Thank you!
Turned off circuit breaker to microwave. (Built-In microwave). Unscrewed four screws at bottom panel of microwave to expose electrical wires/plastic plug to existing microwave motor. Disconnected plastic plug/clips to motor and microwave lights(to allow entire bottom panel to drop down fully from back hinges). Unscrewed mounting screw for motor and removed old motor. Replaced motor and screwed mounting screw back in. Re-attached electrical connections for motor and lights. Closed panel and screwed bottom panel back on. Turned circuit breaker back on. 15-20 minutes start to finish.