Models > MDH15FN1

MDH15FN1 Frigidaire Dehumidifier - Overview

Sections of the MDH15FN1

[Viewing 4 of 4]
Keep searches simple, eg. "belt" or "pump".
Red Indicator Light Lens – Part Number: 318250801
Red Indicator Light Lens
PartSelect #: PS2349641
Manufacturer #: 318250801
$4.20
  In Stock
Compressor Start Relay – Part Number: 216594300
Compressor Start Relay
PartSelect #: PS426380
Manufacturer #: 216594300
$33.65
  In Stock
Humidistat Control – Part Number: 5303296823
Humidistat Control
PartSelect #: PS462294
Manufacturer #: 5303296823
This control needs to be replaced if the dehumidifier won't shut off.
  No Longer Available
SCREW – Part Number: 5303015427
SCREW
PartSelect #: PS453517
Manufacturer #: 5303015427
$8.77
  Special Order
Auto Shut Off Switch – Part Number: 5308016437
Auto Shut Off Switch
PartSelect #: PS474326
Manufacturer #: 5308016437
  No Longer Available
SCREW – Part Number: 3002801
SCREW
PartSelect #: PS432190
Manufacturer #: 3002801
$7.65
  Special Order
TRIM – Part Number: 3002958
TRIM
PartSelect #: PS432193
Manufacturer #: 3002958
$6.87
  Special Order
EVAPORATOR – Part Number: 3017954
EVAPORATOR
PartSelect #: PS433594
Manufacturer #: 3017954
  No Longer Available
CLIP-SWITCH – Part Number: 327100001
CLIP-SWITCH
PartSelect #: PS447831
Manufacturer #: 327100001
  No Longer Available
BASE – Part Number: 5303304132
BASE
PartSelect #: PS464006
Manufacturer #: 5303304132
$44.54
  Special Order
WASHER – Part Number: 08002956
WASHER
PartSelect #: PS411184
Manufacturer #: 08002956
$2.37
  Special Order
NUT – Part Number: 08012645
NUT
PartSelect #: PS413415
Manufacturer #: 08012645
$2.37
  Special Order

Questions And Answers for MDH15FN1

Be the first to ask our experts a question about this model!

Common Symptoms of the MDH15FN1

[Viewing 2 of 2]
Won’t start
Fixed by
these parts
Fixing
Show All
Will Not Start
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The compressor would not run.
I removed the cover, used a multimeter to test the compressor circuit, and found the compressor start relay to be defective.
Ordered a new one and installed it when it arrived.
Parts Used:
Compressor Start Relay
  • Linda from Gurnee, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor was short cycling
Removed the cowling with a square drive screw driver, removed the spring clip from the cover of the compressor controls with a screw driver, pulled off the old compressor start relay and replaced it with the new part. Since other problems could have caused the compressor to short cycle this was a "replace the part and hope it would work" since that would be the most common reason and it was not a very expensive part.
Parts Used:
Compressor Start Relay
  • Sherman from Tuttle, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would run continuously and not shut off
Removed the front cover and then the humidistat from the bracket. Two push on wire connectors and then reversed. Very straightforward and excellent part matching. Given the prices for new dehumidifiers it was great to breathe life back into this unit which does its job well. Thanks for the easy to use web site and fast fast service!
Parts Used:
Humidistat Control
  • Jonathan from New Oxford, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?