Leanna
January 17, 2023
What part do I need if my oven will start to heat but then pilot turns off after a minute or two?
For model number JGBS04PPM2WW
Hello Leanna, thank you for contacting us. The issue is most probably related to the thermocouple, part number PS1559712. It monitors the pilot light to ensure it's lit and closes the gas valve if it detects a loss of flame. We would also recommend checking the oven pilot, part number PS2321352, and thermostat and safety valve assembly, part number PS953421. Customer service is available 7 days a week if you require assistance placing an order. Thanks again for reaching out!
Sadly, we had order the whole burner assembly , when it was just the thermocouple that was burn up. Pull oven away from wall, access burner assembly, take panel off behind control knobs (4 screws)to expose thermocouple. Install new copper line (thermocouple is attached) in same place where old line comes out. This was kind of tricky , you have to fish it through the insulation. One half goes down to oven burner and one goes to top of oven for stove top burner. Once in place, screw nut down on both ends to hold in place. Put it all back together. No need to replace burner unit if that was not the problem. Now you have a spare.
My husband and I simply took the burner units out of the packing, took the old ones off, put the new ones in. The new units needed to be leveled, but the leveling nuts included fit perfectly, and the entire repair took less than 15 minutes.