I went to a GE repair center to explain my problem, the service center reccomended that I have a techinician come out o look at it. $75.00 for the visit and what ever labor and materials wuld cost.
I went on line to see if there were others having this same problem and found that there were many with the same problem.
After reading some of the ways that people found out what was wrong ...it became a matter of three components, the timer, heater or thermostat.
I tried the most common component and the less expensive one first , the thermostat switch I installed it very easily snipping two wires and attaching the news using wire nuts I used the diagram on this website to pinpoint the component and there has not been a problem since.
First, unplug the refrigerator. Next, remove the lower panel on the back of the refrigerator that covers the compressor, condenser and fan compartment. Looking at the refrigerator from the back, the condenser fan is at the lower right corner. There is no information about removing the fan motor, so it took a bit of study. It became obvious that the plastic fan venturi (panel with hole in it for fan blade) needed to be removed. There were two screws that held the venturi panel in place. After removing these screws the top half of the venturi panel could be bent down and pulled from the cabinet. Note that there are tabs and slots on the bottom of this panel that will need to be matched up when replacing the panel. Next the fan blade needed to be removed. This is done by pulling firmly on the balde and it separated from the motor shaft. The most difficult problem was to remove the motor from the motor bracket. There is very little room to remove the two phillips head screws from the front of the bracket, so I used a socket ratchet wrench with an adapter that would hold a phillips bit. This allowed me to remove the screws which were at a right angle to the wrench handle. It took quite a few incremental ratchet movements to remove each screw. After the screws were removed, the motor and wire could be removed by prying the plastic motor bracket apart. There is a insulated cover that is tie wrapped over the motor plug. This was removed and the plug was removed. The steps were reversed to install the new motor. Be sure the venturi panel is positioned correctly and that the fan blade is pushed firmly onto the motor shaft.