This light bulb is for microwaves.
Light bulb illuminates the surface below the microwave or the interior of the microwave.
Because high-voltage capacitors in a microwave can retain a lethal electrical charge even when the microwave is unplugged, a service technician should install this part unless the owner's manual includes instructions for installing the light bulbs.
This round glass tray fits select microwaves and measures about 13 1/2 inches across. It holds food and turns during cooking to help heat it more evenly. The tempered glass has grooves underneath that connect with the turntable support or center coupler. Replace the tray if it is cracked, chipped, broken, or no longer turns correctly.
This microwave door switch works with the door latch to control when the appliance can run, a worn switch may cause the microwave to lose power, fail to start, or trip a breaker, it fits select upper and lower switch locations, high voltage may remain inside the microwave after power is removed, use a trained technician for installation, confirm fit with the exact model number.
Sold individually. Product Description Charcoal air filter works with some Frigidaire, Electrolux, White Westinghouse, and Tappan models of microwaves. This is a genuine OEM part that works for some models of Frigidaire, Electrolux, White Westinghouse, and Tappan models.
This microwave waveguide cover protects key internal components by blocking food particles, grease, and moisture from entering the waveguide area. Located on the interior wall of the microwave, it helps ensure safe and efficient operation. Replacement is recommended if the cover is cracked, burned, or causing sparking, helping prevent further damage and maintain proper performance.
A loose door, repeated clicking, or intermittent operation can indicate a damaged latch body or switch holder. The housing aligns the safety switches with the door hooks and helps prevent operation while the door is open. First inspect the latch opening, door alignment, mounting tabs, and switches to identify every damaged component. Matc...Read moreh the replacement to the microwaves full model number and verify what the assembly includes. Unplugging does not remove the high-voltage capacitor hazard, so professional service is recommended. Do not test the appliance with covers removed or safety interlocks bypassed.
This coupler is a replacement mechanical component used to connect and transfer motion between internal assemblies. It is commonly replaced when wear causes slipping, noise, or loss of function.
Sold individually. This grease filter is for microwaves.
Grease filter traps grease from the exhaust air.
Follow the instructions in the owner's manual when installing this part.
Ask our experts a question about this model and we'll get back to you as soon as possible!
We may have answered a similar question already! Search questions and answers left by others using simple keywords like "fit", "broken", "easy", or "quality" to find questions that match.
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Sort by:
Prev
1
2
3
Next
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
John - For model number FGMV175QFA
December 7, 2019
Microwave blow house breaker when trying to turn on
Hi John, check to make sure its not on an overloaded or faulty circuit, otherwise it could be a multitude of parts overdrawing power. You would need a technician to take a look to make sure. Thank you for your question and good luck with your repair!
Microwave is running and sometimes when we open the door the breaker trips. I checked the switches and they seem fine. Continuity is good. There are two thermal switches. The one on the left has continuity bur the one on the right does not. Would this do it. It’s a vent hood thermal fuse. I looked this up and i don’t think this should have continuity when tested. Something to do an open thermal fuse or a closed one. If the thermal fuse is supposed to have continuity, ( it doesn’t) would this trip the breaker? It’s not blowing the main fuse. Dave
Hello Dave and thank you for writing.
It certainly sounds like it could be a faulty line fuse PS5136235, you should check for signs of damage, and replace if necessary. Also, consider this (does not happen often but it does): The breaker in your panel box might be defective. Plug your unit into a separate circuit (breaker) and see if it still trips the other breaker, this way you know for sure. We hope this helps. Please contact us anytime.
Is there a replacement piece for the number pad. Mine is scratched really bad. It looks like a piece of plastic covering the numers
Please let me know cause its not pretty anymore
Hello Betty, thank you for your inquiry. The touchpad for your model is showing as PartSelect number PS9492497. We hope this helps.
2 peoplefound this instruction helpful.
Was this helpful?
Thank you for voting!
Larry - For model number FGMV175QFA
December 21, 2019
Clock will not keep correct time which and will take a minute or 2 to start after entering time to cook. Would like to know part number for control.
Hello Larry and thanks for writing.
It certainly sounds like a door latch issue PS2582995 you should check for signs of damage, and replace it if needed. We hope this helps. Please contact us anytime.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Microwave tripped circuit breaker when turned on
41 of 68 peoplefound this instruction helpful.
Arthur from LUTZ, FL
Easy
15 - 30 mins
Screw drivers
Remove vent cover then remove touch screen control panel. When you remove control panel take photo of where everything is plugged in then unplug and remove control panel. 3 door switches located next to door in a plastic chassis. Test each switch with current tester. Remove the bad switch and replace with the new one. You tube DIY helped.
Was this helpful?
Thank you for voting!
Power would not come on, would trip breaker when connected.
18 of 28 peoplefound this instruction helpful.
JOSEPH from MIAMI, FL
Easy
15 - 30 mins
Screw drivers
First thing I dir was search YouTube for any related videos and found this one https://www.youtube.com/watch?v=uHj4H9Fdxrc, it was the exact problem my microwave was exhibiting. Once I verified the problem by troubleshooting, I removed the part and verified that the switches were working fine, the door latch assembly showed signs of wear
... Read morewhich was the cause of the problem. After receiving the replacement part I installed it, verified that power was restored to the unit and reassembled the microwave, works fine, hope it lasts a long time!
Read less
Was this helpful?
Thank you for voting!
Pressing the start, microwave will start and dies out. Electric is tripping.
11 of 18 peoplefound this instruction helpful.
ARNEL from WAUKEGAN, IL
Easy
15 - 30 mins
Screw drivers
The diagnosis is about an hour. Coz, I need to open the control panel, got a tester, and trsted all critical parts inside the panel. Also, replaced the fuse just to make sure its a new one. Found out it was a switch (bottom part) that control the open/close of the microwave door.
When found out the problem, the rest of t
... Read morehe work is easy.