This interlock switch ensures safe operation by confirming that doors or panels are properly closed before the appliance can operate. It is commonly replaced when the appliance will not start or stops unexpectedly.
This turntable motor is for microwaves.
The turntable motor rotates the glass tray inside the microwave oven.
Because high-voltage capacitors in a microwave can retain a lethal electrical charge...
Are you concerned about your microwave starting up with the door open? Let us help you solve this problem with our GE Microswitch Monitor. This piece is designed just for safeguarding your home by sto...
If your microwave suddenly stopped working, this 20-amp fuse might be the reason. It’s designed to blow when there’s a power surge, protecting your appliance from damage. This genuine part fits many G...
Make sure your microwave heats food evenly with this 13.5-inch glass turntable tray. It’s made from durable, heat-resistant glass and fits many GE and Hotpoint models. The underside has three grooves ...
This waveguide cover protects the microwave’s internal components by shielding the magnetron from moisture, grease, and food splatters, helping prevent sparking and ensuring efficient heating. Made fr...
No Longer Available
Questions And Answers for CEB515P4M1WM
Be the first to ask our experts a question about this model!
✖
Ask a Question
Ask our experts a question on this model and we'll respond as soon as we can.
REPLACE SWITCH -STAND ON (NOT THE SWITCH-MONITOR) THERE ARE TWO OF THESE SWITCHES THE TOP ONE WAS DEFECTIVE. THE ON OFF SWITCH BUTTON ON THE SWITCH WAS BROKEN
1. Take out the case by unscrew 8 screws on the back and side of the case 2. Take out the control panel by unscrew 1 screw on the top and slide up 3. Take out the latch by unscrew 2 screws, and slide out 3 electric switches that clipped on the latch 4. Clip the switches onto the new latch 5. Slide in lever switch into latch 6. Put back the latch 7. Put back the control panel 8. Put back the case
Slide a Butter knife at left side by open push knob door will open. Then open all screws from top cover push cover top side front way then door locks Bracket have 3 microswitch pulls out switches mark them top medium and bottom. Remove 3 screws holding brackets will come out. On bottom see a Cam has 1/4” holes can holding Saft broken then install new door lock bracket install microswitch put 3screw and slide Cam on saft . I put a small screw on saft to hold cam on place. There was no screw . That’s why cam saft was broke. Put top cover tight all the screws and door lock fixed.