Models > AZ31H06E3DV3

AZ31H06E3DV3 General Electric Air Conditioner - Overview

Sections of the AZ31H06E3DV3

[Viewing 2 of 2]
Keep searches simple, eg. "belt" or "pump".
DISCONTINUED – Part Number: WP12X14
DISCONTINUED
PartSelect #: PS281519
Manufacturer #: WP12X14
  No Longer Available
Fuse – Part Number: WP23X94
Fuse
PartSelect #: PS281806
Manufacturer #: WP23X94
  No Longer Available
Room Thermostat – Part Number: WP26X42
Room Thermostat
PartSelect #: PS281945
Manufacturer #: WP26X42
  No Longer Available
Main Switch – Part Number: WP28X56
Main Switch
PartSelect #: PS282095
Manufacturer #: WP28X56
$254.32
  Special Order
Control Board – Part Number: WP29X70
Control Board
PartSelect #: PS282224
Manufacturer #: WP29X70
$590.19
  Special Order
Discharge Grille – Part Number: WP71X46
Discharge Grille
PartSelect #: PS282688
Manufacturer #: WP71X46
  No Longer Available
FILTER Assembly – Part Number: WP85X15
FILTER Assembly
PartSelect #: PS282880
Manufacturer #: WP85X15
  No Longer Available
GROMMET – Part Number: WJ1X762
GROMMET
PartSelect #: PS274879
Manufacturer #: WJ1X762
  No Longer Available
Mounting BRACKET – Part Number: WP1X47
Mounting BRACKET
PartSelect #: PS281562
Manufacturer #: WP1X47
$20.44
  Special Order
PANEL SIDE R – Part Number: WP82X19
PANEL SIDE R
PartSelect #: PS282863
Manufacturer #: WP82X19
  No Longer Available
EVAP CVR Assembly – Part Number: WP79X67
EVAP CVR Assembly
PartSelect #: PS282822
Manufacturer #: WP79X67
  No Longer Available
PLATE PART – Part Number: WP65X11
PLATE PART
PartSelect #: PS282434
Manufacturer #: WP65X11
$123.66
  Special Order

Questions And Answers for AZ31H06E3DV3

Be the first to ask our experts a question about this model!

Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Appliance would not shut off- heated or cooled just fine but never turned off.
Turn off the circuit breaker. 1- Removed cover- (clips on both sides of bottom front pop loose and carefully lift off) 2. Remove knobs. Unscrew the lock washer on the switch pegs 3. Unscrew all visible screws approx 4 in front and 2 on the side 4. This will allow you to jar the aluminum box loose from the top- it does not come off completely. 5. Carefully locate the switch-circuit board behind the left knob. 6. Unplug both lines- insert new part (main switch) connect both lines into the new part. 7. Replace the box just as you took it apart. 8. Make sure the knob pegs are turned all the way to the left. Reinstall lock washer. Then align knobs on appropriate pegs.turn on the circuit breaker. Check that knobs are aligned properly and turn on - let it run so that it would shut off as you raise or lower the heat or cool. If it shuts off- yeah it is fixed!!! Replace the cover carefully after a thorough cleaning. You are DONE!
Parts Used:
Main Switch
  • JEANIE from LAQUEY, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Wrench (Adjustable)
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!