Russell
October 24, 2024
oven will not heat beyond 100°
For model number AGG222VDW6
Hi Russell,
Thank you for your question. If the oven is not heating correctly, the issue may be with the oven sensor. The oven thermostat is the part that monitors the oven temperature and signals the electronic control board to turn the elements on and off. Before removing this part from the oven and testing it with a multimeter for continuity, unplug the oven from the electrical outlet. A normal reading should be 1100 ohms, but as readings vary from model to model, you will need to reference your owner’s manual to determine what the correct reading should be. To test it for continuity, use a multimeter on the Rx1 setting and touch the terminals with the probes. This test needs to be done with the oven thermostat at room temperature to produce accurate results. If your test results do not meet the manufacturer’s guidelines, you need a replacement oven thermostat. If the thermostat is fine, you will need to check the elements, the electronic control board, and the wiring between the parts to see which one is causing the issue. We hope this helps with the repair!
Replace two igniters that were not working. Did not fix the problem. Swapped wire positions from Spark Module and noted that the problem followed the igniter positions. Replaced Spark Module. Problem solved. Procedure required disconnecting a/c power, removing four screws, removing igniter wires from old module and reconnecting them to new module. Reinstalled new Spark Module in range. Reconnected a/c power. Test successful. Total time: 20 minutes.