This is a genuine replacement switch. It is a push button style switch that is designed for use in your refrigerator. When the door of your appliance is opened the switch is released, and the light co...
This handle screw, also known as a mounting bolt, is a mounting screw to help secure the door handle to your refrigerator door. If your handle is loose, you may just need to tighten the screw. If your...
Ask our experts a question about this model and we'll get back to you as soon as possible!
3 questions answered by our experts.
< Prev
1
Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Karen
June 30, 2021
Not dispensing ice, and items in the freezer are defrosting.
For model number 79571039010
Hello Karen, Thank you for the question. We suggest testing the Defrost Sensor Assembly. It should read on a meter 30KO at 32°F, 24.1KO at 41°F, and 8.9KO at room temperature. We hope this helps!
ice maker not making ice. Already tried reset button.
For model number 79571039010
Hello Anna, Thank you for your inquiry. It could be an issue with either the water inlet valve or the ice maker. We have included a link to our video on how to test the water inlet valve with a multimeter and how to test the ice maker. We hope this helps and if you need help placing an order for a part, customer service is open 7 days a week. Please feel free to give us a call. We look forward to hearing from you!
Freezes In the winter but not in summer..garage refrigerator now
For model number 79571039010
Hi Will, thank you for contacting us. We have found that there are evaporator coils and a circulating fan in the freezer zone of the refrigerator. Poor cooling can be a result of excessive frost development on the evaporating coils. Over time, frost accumulates over the coils and fan. When frost accumulates over the evaporator coils, they get insulated. Due to this, the circulating fan is unable to draw air over the frosted coils. We would recommend checking the frost buildup on the coils and ensuring proper ventilation of the refrigerator. If this is not the issue, you may need to check the evaporator fan motor, part number PS3523323, to fix the issue. We hope this solves your problem!
1. Shut off water to refrigerator. 2. Removed bottom sheet metal cover (6 screws). 3. Removed leaking water inlet valve assembly from refrigerator (1 screw). 4. Remove water inlet tube (loosen nut) and tube back to refrigerator (pull from water valve after remove cotter pin washer). 5. Detach two electrical wire harnesses. 6. Install new water inlet valve assembly to refrigerator (1 screw). 7. Replace both water tubes to water inlet assembly. 8. Re-attach both wiring harnesses. 9. Turn water to refrigerator on. 10. Check for leaks. 11. Re-attach bottom sheet cover (6 screws).
Turn off power, remove upper and lower drawers (may need to open upper refrigerator doors to remove large freezer bin,) remove drawer supports (upper and lower), remove rear freezer panel (trick is to loosen 4 screws on fan bumpout to get the panel to come free from the freezer side wall), test thermistor with multimeter (should have continuity or near zero resistance across 2 orange fuse wires) before cutting zip ties, cut zip ties holding Thermistor in place, remove old Thermistor, install new Thermistor, install new zip ties, replace rear freezer panel, install upper and lower drawer supports, install drawers, turn on power, should be fixed if error code doesn't return after 6 hours.
Shut off water supply. Disconnect main supply line. Remove rear lower panel on back of refrigerator. Remove all tubing clamps on back. Disconnect leaking tubing from water supply valve. Remove water filter and unscrew/remove water filter housing. Replace tubing - connect to water filter housing then to water supply valve. Reconnect filter housing and filter. Reinstall lower panel, then main water supply line, then all tubing clamps. Turn water back on and check for leaks after discarding several glasses of water to fill filter. Job complete!