This element has looped terminal ends and comes with a black medallion center. This element is a genuine OEM replacement part, has looped terminal ends, comes with a black medallion center, and fits m...
PF alarm appeared on display. Noticed clicking when cord was moved. Had arced for some time and melted original block. New part slightly different. Only has 3 lugs, old one had six. Stack using washers provided. Take note of colors before disassembly. Use caution while working through access opening. The edges are sharp. Only tools needed are phillips screwdriver, deep socket for lug nuts. Nut driver optional. Hope this is helpful.
Turned off power, took back off stove removed old probe. I had to splice wires since new probe ends did not match up. the instructions were to splice the wires. I had the breaker off for about 3 hours. this is not in the instructions, but being a widow, I had to ask a few people why it would not come on after I connected the wires. After waiting, I turned the breaker on and my range came back on.
Pulled stove out. Removed screws(5) holding top unit. Tipped top unit to get at the control panel. Removed screws holding control panel. Removed wires from old one and put on to the new one. Reinstalled top panel and turn breaker back on.PS I didn't order a new face panel so had to gentley remove from the old and put on the new panel(before reinstalling). I would suggest getting a new one when ordering this conrtol panel.