Microwave operated but did not heat
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Parts Used:
Fuse,Time Delay
  • Donald from Oak Ridge, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
1 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Insulator cover was eroded and sparking
Insulator cover was eroded and sparking. Found on web that problem is insulator becomes water/vapor logged and sparks/erodes. Fix: Plastic pin connectors pulled out w/ fingernails. Old insulator required gentle prying to loosen. New one fit right in. new connectors pressed in w/ finger pressure. Good as new! First shipped part was in flimsy enveloped and arrived bent. Had to RMA and get new one shipped. New one arrived in box, just fine.
Parts Used:
Rivet Cover,Insulator
  • Bill from Seattle, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
dead unit
replaced the part thank you.
Parts Used:
PCB ASSEMBLY,SUB
  • Julio from naples, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
replacement microwave turntable
thank you for a followup you are definitely unique in companies. A quick delivery.
Parts Used:
Tray,Glass
  • Kathleen from Windermere, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?