Models > 580547018

580547018 LG Dehumidifier - Overview

Sections of the 580547018

[Viewing 3 of 3]
Keep searches simple, eg. "belt" or "pump".
Sensor – Part Number: 6877A30013V
Sensor
PartSelect #: PS3654111
Manufacturer #: 6877A30013V
Also known as thermistor.
$58.92
  Special Order
Power Cord Assembly – Part Number: 6411A20001Z
Power Cord Assembly
PartSelect #: PS3529049
Manufacturer #: 6411A20001Z
$42.91
  Special Order
Switch Assembly – Part Number: 6600A30003C
Switch Assembly
PartSelect #: PS3529251
Manufacturer #: 6600A30003C
  No Longer Available
Overload Protect – Part Number: 6750U-L048A
Overload Protect
PartSelect #: PS3529568
Manufacturer #: 6750U-L048A
$58.94
  Special Order
Motor Assembly,AC – Part Number: EAU32357504
Motor Assembly,AC
PartSelect #: PS3533521
Manufacturer #: EAU32357504
$148.74
  Special Order
Filter,Air – Part Number: 5230A20040A
Filter,Air
PartSelect #: PS3527502
Manufacturer #: 5230A20040A
$18.82
  Special Order
ROLLER – Part Number: MHA62753001
ROLLER
PartSelect #: PS11712156
Manufacturer #: MHA62753001
$31.17
  Special Order
Nut,Common – Part Number: FAD00019002
Nut,Common
PartSelect #: PS3534423
Manufacturer #: FAD00019002
$5.88
  Special Order
Harness,Single – Part Number: 6862A20013R
Harness,Single
PartSelect #: PS3529605
Manufacturer #: 6862A20013R
$11.74
  Special Order
Harness,Single – Part Number: 6877A20025L
Harness,Single
PartSelect #: PS3530173
Manufacturer #: 6877A20025L
$28.86
  Special Order
Cover – Part Number: 3550UTL006A
Cover
PartSelect #: PS3520116
Manufacturer #: 3550UTL006A
$17.59
  Special Order
Handle – Part Number: 3650A20004A
Handle
PartSelect #: PS3521071
Manufacturer #: 3650A20004A
$8.31
  Special Order

Questions And Answers for 580547018

Be the first to ask our experts a question about this model!

Common Symptoms of the 580547018

[Viewing 2 of 2]
Unit says bucket is full when it isn’t
Fixed by
these parts
Fixing Fixing
Show All
Won’t stay on
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
bucket full light constantly blinking with error code 01 on the display
Unscrew and detached front and back panels, and inside framework holding the sheet metal to the body, after removing the sheet metal, unscrew the box enclosing the control board, use needle nose pliers to unhook the sensor module from the board and place the new sensor into the spots where the old sensor was connected (thermostat area, humidity Sensor, bucket switch, and control board). Close up the unit and your good to go.
Parts Used:
Sensor
  • Seif from DETROIT, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken roller wheels
released broken wheels from their position using a screwdriver and secured new ones w/ a pliers.
Parts Used:
ROLLER
  • MICHAEL from LEBANON, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
bucket full light was blinking and dehumidifier would run for a few seconds then turn off
remove outer shell and control panel. take cover off off electrical connection box. remove old sensor from front of condensing coil along with wiring harness to temperature sensor and bucket switch and circuit board. reinstall new sensor in the reverse procedure. reinstall covers.
Parts Used:
Sensor
  • Larry from North Ridgeville, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!