I unplugged electrical cord to the freezer. I removed the cover to the relay and load protector. I labeled the wires and made a diagram on the proper placement of each wire going to the relay. I unplugged each wire and removed the relay. Then I removed the load protector. I installed the new load protector and new relay. I placed the wires on the proper terminals of the relay. I replaced the electrical cover to the relay and load protector. I plugged the electrical cord back in the electrical outlet. My freezer started working again. I placed several bottles of water in the freezer to make sure the freezer was working properly before I restocked it with food.
Thanks again for the help. You just saved me about $400.
Remove the 6 screws with a 5/16 inch nut driver. Make sure the lid gasket is in full contact all the way around. Remove any ice interfering with the lid gasket mating properly. Install new hinge using the original screws. Have somebody hold up the lid and tighten the spring nut with a deep 1/2 inch socket gradually until the lid stays up by itself.