evaporator coil kept freezing up, refridgerator warm.
This was the second part I tried. The defrost timer was first, but that did not fix it. To do this I had to remove the ice maker and the back plate of the freezer. Then I defrosted the coil and cut the wires. stripped them back and installed the new thermostat. re-assembled and tested. has been working great ever since.
Parts Used:
Defrost Thermostat
  • Greg from Hanover Township, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
182 of 200 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would not run but interior light was on.
I unplugged the refrigerator, then opened the door and removed four screws holding the plastic electrical panel to the interior top of the main refrigerator compartment and noticed the cold control was corroded badly, apparently from moisture in the panel. I ordered a new one from partselect.com. When it arrived the next day, I then pulled off the control knob, unclipped the cold control, unplugged the three wires to the control, then removed the styrofoam insulation blocks holding the thermocouple wire and then removed the thermocouple wire to complete the removal. I then reversed the process to install the new thermostat and control. That is repositioned the thermocouple wire, put the insulation blocks back to hold the wire, then replugged the three electrical wires, clipped the control back and pushed the control knob back on and finally screwed the panel back to the top of the main compartment and plugged the refrigerator electrical cord back in to provide current to the refrigerator. It immediately started up and ran fine. Total time - about 8 minutes.
Parts Used:
Cold Control Thermostat
  • Bruce from Alton, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
179 of 232 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not cooling, Freezer working fine
Frig area was at about 50 degrees and would not get cooler. Freezer was working great.
Empty the freezer and remove the two screws that hold the back panel of the inside of the freezer on. Pull the panel out and you will see the fan that is mounted to the back of the panel. If the fan is not running, disconnect it (quick connector) and check to see if there is voltage coming to it from the connector (should be 120VAC between the two wires). If there is power, and the fan was not working, replace the fan.

Fan just snaps into the holder on the back panel and plugs into the quick connector. Make sure you clear any ice build-up in the hole between the freezer and the frig that the fans blows through. Put it back together and verify the fan runs.
Parts Used:
Evaporator Fan Motor
  • Roger from TRURO, IA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Socket short
- Unsnapped old light socket from top of Frig
- Disconnected elect wires
- Reconnected elect wires to new light socket
- Snapped new socket in place
- Done in less than 2 min.
Parts Used:
Light Socket
  • Rebecca from Gautier, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer seemed ok, though frosty, but the bottom section was not cold enough, and the compressor seemed to run constantly.
The lower compartment was hovering around 50 degrees. Logic told me that cold air was not being driven from the freezer to the lower compartment. At first, I found the passageway between freezer and lower compartment was blocked with frost/ice, which could have been the entire problem. But why was that ice accumulated there? After defrosting, the problem was only partly solved. A few how-to videos suggested that the defrost timer was a common problem, so I tried that, the part was about $11, with minimal improvement. So I concluded that the fan was not driving cold air from the freezer to the lower section. I tested the fan by removing the freezer back panel completely, wiring the fan to an old ordinary power cord, and plugging that in to a wall outlet. The fan would not start on its own, would only turn if I gave it a spin, and then was very weak - I could stop it with a finger without pain! When my new fan arrived, I again removed the back panel in the freezer and replaced the fan, just a few screws to remove, then swap the fan blade to the new fan motor. The process was simple and obvious. Now the lower section stays near 40 degrees, though I'm not convinced that's the only problem-there seems to be a lot of variation in the temperature. BTW, I had also confirmed the defrost heating element was functional by activating the defrost timer (see youtube), to eliminate that from the diagnosis.
Parts Used:
Evaporator Fan Motor Defrost Thermostat
  • Gary from GRASS VALLEY, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
17 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the shelf bar broke
I popped the new one in. My cat could have done it
Parts Used:
Door Rack - White
  • Jeff from New Yrok, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
18 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Freezing up and blocking the vent for refrigerator, not cooling the fridge.
Went pretty straight forward, except the heat shrink tubing was about 2 sizes too big. Would not shrink small enough to seal the connections. Even with a heat gun it would not shrink small enough. OH, another think is when I plugged the fridge back in the defrost timer was in defrost mode. Took me a few minutes to figure that out and use a screwdriver to turn the timer back to the on position. Other than that, install was pretty simple.
Parts Used:
Defrost Thermostat Defrost Timer - 120V 60Hz
  • Dennis from BEAUMONT, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
16 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Plastic fan broke
took the cover off
(cardbord) the fan will come off and go back on by hand no tools needed i changed the fan motor just to be sure. 3 little screws hold it on. the plug only goes on one way u can't mess it up.very easy job u shouldn't have any problems doing it.Jim
Parts Used:
Condenser Fan Motor BLADE-CONDENSER FAN
  • James from GLEN FLORA, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set, Wrench set
13 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven light bulb went dark; it needed replacing
Twisted replacement bulb into place easily. Let there be light!
Parts Used:
Light Bulb
  • Lise from CEDAR GROVE, NJ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coming from the refrigerator, there was an intermittent "clicking noise", occurring about every 30 seconds. The frig. eventually failed .
I removed the back cover and removed the clip holding the compressor- run capacitor and start relay. I replaced these 2 components and clean the dust from the frig., and from the bottom of the floor. I replaced the back cover ; Loss about $300 worth of meat when when the frig. failed. Then I thought that, during these turbulent times, there are many which don't have a refrigerator or any meat to place in it, The refrigerator is "running" normal again.
Parts Used:
Run Capacitor - 120V
  • winifred from LOUISVILLE, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
One blade broke from condenser fan
The part i recieved, from parts select was a larger in circumfrence (<1/4) than the original. However i was not aware of this until after i treid to repair it.

I removed the broken fan from the condenser. This was very sipmle.

When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
Parts Used:
BLADE-CONDENSER FAN
  • Chris from Lockport, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
10 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
Parts Used:
Light Bulb
  • ANGELA from MEBANE, NC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not running
After waiting over 2wks for my part to arrive, I purchased the part locally and made the repair the same day as I am still waiting for the part to arrive from you guys. Your customer service really needs improving. I paid for 2 day shipping, what a joke. I will be returning the part as soon as I receive it thanks.
Parts Used:
Cold Control Thermostat
  • Kenneth from SAVANNAH, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I want to mention this is a garage ref with freezer on top. Freezer was to warm 20-32 deg.
Replaced thermostat and defrost timer and still freezer to warm.
After research with U-tube video of (Fixin it with Pappy) discovered that my fridge has one thermostat in fridge section and in cold months (live in ohio)the garage is cold therefore themostat in fridge does"nt need to tell the compressor to kick on. Pappy is a retired engineer and in very easy to follow instructions will show you how to fix this problem. Strongly suggest to search for his video on Utube. I did as he instructed and my fridge freezer works great in cold weather now. Its apparent to me I wasted my money on the parts. I didn't` need to replace. Just happy my Beer fridge is working all seasons now.
John from Ohio
Parts Used:
Cold Control Thermostat Run Capacitor - 120V
  • John from S CHARLESTON, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken restrained rack
The old one popped out, the new one popped in. As easy as that.
Parts Used:
Door Rack - White
  • Anthony from LANCASTER, OH
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.