This hose clamp extends from half an inch to an inch in diameter. It is made entirely of metal and is intended for use with Maytag brand washing machines.
1) Unplug power cable from dryer. 2) Remove the 2 screws that secure the chute for lint filter screen with Phillips head screwdriver. 3) Remove the lint filter screen. 4) Depress plastic locking clip on each side with putty knife to release tension and lift up top panel to clear the locking clips. Each locking clip is located 2-1/2 inches from the front edge of side panel. 5) Lift the top panel and lean against the wall for support. If dryer top panel cannot be raised all the way due to cabinet(s) above, tape the dryer top panel to cabinet above or have somebody hold the top panel for temporary support. 6) Install the new metal locking clips. Ensure that the elongated tab of the metal locking clip is towards the front of dryer. Compress locking clip lightly with pliers and push down into the hole. 7) Lower the dryer top panel and press it down in place over the metal locking clips for a tight fit. 8) Reinstall the 2 screws to secure the lint filter chute. 9) Reinstall lint filter screen. 10) Reconnect power cable for dryer. 11) Turn on dryer and inspect that all dryer panels (top, sides and front) are tight and secured. Repair Duration: 5 minutes
First used wet vac to get water out. Unplug electrical cord. Shut off water and unhook lines. Unhook drain tube. Flip over on side. Take belt cover off. two screws. Took photos of parts removing just for re- install. Ordered parts from part select.com. Came in Two days. The dealer was on 12 days I gave up on them. I removed actuator two easy screws and pulled off electrical connection no tool needed. Then removed pump three longer screws Than other part. Make sure to label them in a ziplock baggie. Plus I removed hose clamp with pliers slide Back on hose and pull hose off. Then remove electrical connection on pump. If it makes you feel better label each with masking tape so I know where each connection goes. Then replace pump first with new one. Make sure you push it in hard then the screws. Don’t over tighten. Plastic parts break. Hook back up hose slide clamp back over fitting end with pliers. Hook up wire connector. Next hook up actuator. Two screws wire connector and your done. Put belt guard back on. Socks can get caught under washer get in belt and cause major issue. Then you need to reconnect water lines. Make sure hot goes to hot. Cold to cold. Drain hose hook back up. Plug in power cord. Now the fun part. Run a diagnostic and then calibration. See you tube videos it’s like 3 clicks to left then two to right with selector knob. Write down the exact amount of clicks and steps. It works. Be sure to turn knob 4 times to left to clear it like a combination lock. Don’t let the noises scare you it makes all Kinds of sounds while calibration goes on.