1069430012 Kenmore Refrigerator - Overview

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Light Bulb - 40W – Part Number: 8009
$26.41
In Stock
Light Bulb - 40W
★★★★★
★★★★★
(47)
Part #8009
This an authentic OEM 40-Watt replacement light bulb, used in a number of household appliances. It is specially designed to withstand extreme temperatures, which is why these replacement bulbs are most often used to light the inside of refrigerators and ranges. It features a standard socket base, which means you simply unscrew the burnt-out bulb and screw in the replacement. Depending on the appliance you may require a screwdriver or nut driver to access the light bulb. We recommend you wear work gloves while handling this replacement part. It is constructed of glass and metal and is sold individually. Depending on the appliance and location of the bulb within it, you may want to consider disconnecting power and using a flashlight for easier access to unscrewing and re-screwing in your bulb during this repair.
Touch-Up Paint - White – Part Number: 72017
No Longer Available
Touch-Up Paint - White
★★★★★
★★★★★
(23)
Part #72017
This 18 ml bottle of white appliance touch-up paint is used to cover scratches or marks on your appliance. The white touch-up paint can be used on refrigerators, microwaves, ranges, clothes dryers, and freezers. This is a genuine OEM part and includes a brush applicator. Please remember to wear gloves to protect your hands when applying this paint.
Refrigerator Bimetal Defrost Thermostat – Part Number: WPW10225581
$48.43
In Stock
Refrigerator Bimetal Defrost Thermostat
★★★★★
★★★★★
(18)
Part #WPW10225581
If ice is building up in your freezer or if your freezer is getting too warm on the defrost cycle you may need to replace the bi-metal thermostat.
Defrost Timer – Part Number: W10822278
$45.92
In Stock
Defrost Timer
★★★★★
★★★★★
(12)
Part #W10822278
This eight-hour defrost timer will replace most other defrost timers. This device acts like a clock. It continually advances and alternates between activating the cooling cycle and the defrost heater. The best way to make sure you get the correct timer for your refrigerator is to conduct a search for your model number. NOTE: The black lead on the defrost timer, will go to terminal number 2.
Refrigerator Thermostat Assembly – Part Number: WP2198202
$94.98
In Stock
Refrigerator Thermostat Assembly
★★★★★
★★★★★
(25)
Part #WP2198202
The thermostat will sense the temperature increase in the evaporator during the defrost cycle and will cycle the defrost heater off after the ice or frost is melted.
Screw – Part Number: W11233072
$30.40
In Stock
Screw
★★★★★
★★★★★
(5)
Part #W11233072
This is a multi-use and multi-appliance screw. It can be used on a microwave, refrigerator, range/oven, air conditioner, dehumidifier, washer, or dryer. The measurements of this screw are 8 x 1/2 inch. It has 6 threads. Refer to the manual provided by the manufacturer for further information on repair and accurate guidance. Remember to wear work gloves as a safety precaution.
Evaporator Fan Blade – Part Number: WP2169142
$41.53
In Stock
Evaporator Fan Blade
★★★★★
★★★★★
(2)
Part #WP2169142
A warm refrigerator or noisy evaporator fan can indicate a problem with the fan blade. This white, four-blade OEM part circulates cold air over the refrigerators evaporator coils. Confirm fit using your refrigerators model number.
Shelf Support Stud - White – Part Number: 4388538
$34.30
In Stock
Shelf Support Stud - White
★★★★★
★★★★★
(1)
Part #4388538
This kit contains two options - One that is a push and turn and the other that is a screw in.
Add-On Icemaker Assembly – Part Number: 1129316
$153.57
In Stock
Add-On Icemaker Assembly
★★★★★
★★★★★
(5)
Part #1129316
This icemaker kit comes with a flat plug, wiring harness, fill tube, water inlet valve, ice bin, mounting hardware, and instructions.
Evaporator Fan Motor - 120V 60Hz – Part Number: 4389144
$93.67
In Stock
Evaporator Fan Motor - 120V 60Hz
★★★★★
★★★★★
(5)
Part #4389144
This part is located in the back of the freezer, and circulates air over the refrigerator coils. These coils will convert the heat into cool air, which is then circulated. Fan blade not included.
Refrigerator Shelf Support Stud – Part Number: WP2149540
$16.95
In Stock

Common Symptoms of the 1069430012

How this model fails, and the parts that fix it.

Watch our pros, then fix it yourself.

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory! View More

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
inconsistent compressor and condensor fan operation
308 of 327 people found this instruction helpful.
  • Steve earney from Brooks, GA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Compressor start relay would cycle several times before compressor would come on. Replaced start relay and defrost timer assy. Operated more consistently however not completely reliable. Ice would begin to melt. Noticed that if you would cycle the temperature control the compressor would start again and operate for several hours then n ot cycle again. Jumpered temp control and operation was continuous and reliable. Replaced cold control thermostat. Operation now normal. Suspect high resistance in switch caused start relay and timer contacts to arc. Small amount of carbon noticed under temp control...
Was this helpful?
Thank you for voting!
Fridge was getting too warm, ice buildup on coils.
159 of 188 people found this instruction helpful.
  • Cathy from Winter Park, FL
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Was this helpful?
Thank you for voting!
The compressor would shut down and not restart unless you tapped the temperature knob which i did for about 3 weeks before ordering this part
116 of 121 people found this instruction helpful.
  • michael from clarksville, TN
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Was pretty simple just take the knobs off pull off the face plate remove a few screws and drop the whole shelf down. then a few more screws down the side to the back of the fridge. Pull the sensor wire out of some styrofoam and pull off the plastic coating and slide it over the new one and install it in reverse order from taking it out. W orks great now and i have ice everyday :)
Was this helpful?
Thank you for voting!