Light Bulb - 40W
PartSelect #: PS884734
Manufacturer #: 8009
This an authentic OEM 40-Watt replacement light bulb, used in a number of household appliances. It is specially designed to withstand extreme temperatures, which is why these replacement bulbs are mos...
$37.19
In Stock
Lower Door Closing Cam
PartSelect #: PS11739042
Manufacturer #: WP2182179
The lower door closing cam is used in refrigerator doors, it can be located on the fresh food side or the freezer side. It helps hold the door open. This cam is made out of plastic, so it might crack ...
$9.80
In Stock
Refrigerator Ice and Water Filter
PartSelect #: PS11701542
Manufacturer #: EDR1RXD1
This is an OEM replacement ice and water filter for your refrigerator. In side-by-side refrigerators, it is found in the top right corner or the bottom left grille. In bottom-freezer refrigerators, th...
$93.78
In Stock
Refrigerator Crisper Drawer With Handle
PartSelect #: PS11739122
Manufacturer #: WP2188664
This OEM, clear convertible meat drawer can be used to store meats or vegetables and is designed for the lower portion of your refrigerator, generally. It has its own cold air duct to allow cold air f...
$85.67
In Stock
Touch-Up Paint - White
PartSelect #: PS385132
Manufacturer #: 72017
This 18 ml bottle of white appliance touch-up paint is used to cover scratches or marks on your appliance. The white touch-up paint can be used on refrigerators, microwaves, ranges, clothes dryers, an...
$10.18
In Stock
Bi-Metal Defrost Thermostat
PartSelect #: PS11750673
Manufacturer #: WPW10225581
If ice is building up in your freezer or if your freezer is getting too warm on the defrost cycle you may need to replace the bi-metal thermostat.
$59.23
In Stock
Refrigerator Slide-Out Shelf with Glass
PartSelect #: PS11751713
Manufacturer #: WPW10276348
$250.92
In Stock
Refrigerator Compressor Start Relay
PartSelect #: PS11750123
Manufacturer #: WPW10197428
This compressor start relay is for refrigerators. The compressor start relay attaches to the compressor and helps start the compressor motor. Safely store any food that could deteriorate while the pow...
$97.06
In Stock
Gallon Door Bin - Clear
PartSelect #: PS11757236
Manufacturer #: WPW10710203
Sold individually. This door bin is for refrigerators.
The door bin attaches to the inside of the refrigerator door and typically holds jars and bottles.
$54.56
In Stock
Crisper Cover with Glass
PartSelect #: PS4082908
Manufacturer #: W10508993
This part is also known as a shelf frame. This drawer cover is for refrigerators.
Drawer cover has rail brackets under the cover that hold the drawer and allow the drawer to slide in and out on th...
$187.08
In Stock
Screw
PartSelect #: PS11757021
Manufacturer #: WPW10661886
This mounting screw is a genuine OEM replacement part for the door handle in your refrigerator. If you are having trouble shutting the refrigerator door, or opening it, replacing this screw can help s...
$16.17
In Stock
Screw
PartSelect #: PS11742755
Manufacturer #: WP489483
This screw is sold individually.
$16.63
In Stock
Questions And Answers for 10650023211
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
- < Prev
- 1
- 2
- 3
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Ruth
February 7, 2024
Ice maker makes ice but will not dispense it.
For model number 10650023211
Hi Ruth, thank you for contacting us. We believe your refrigerator is having this problem because of the faulty ice dispenser solenoid, part number PS11738908. It shifts the ice container deflector to dispense crushed ice or cubed ice. You may need to replace it to fix the issue. We hope this helps!
2 people found this helpful.
Was this helpful?
Thank you for voting!
Related Parts:
Vivian
February 4, 2020
Need connector for my refrigerator .The one attach to the back of the fridge to the water valve
For model number 10650023211
Hello and thank you for writing.
Water-tube connector PS11740187 is in the list of compatible parts for your model. We hope this helps. Please contact us anytime if you require further assistance.
Was this helpful?
Thank you for voting!
Related Parts:
Keri
February 19, 2020
How do i change the lightbulb inside the refrigerator?
For model number 10650023211
Hello Keri,
Thank you for your question. You will need to remove the control box on the ceiling of the refrigerator by unscrewing it off and then you will be able to access the light bulb to replace. We hope this helps.
Was this helpful?
Thank you for voting!
Related Parts:
Pamela
February 23, 2020
I need hinges for top door of refrigerator for doors. Where can i find them
For model number 10650023211
Hello Pamela,
Thank you for your question. The top door hinges for your model is under part PS12070622. We hope this helps.
Was this helpful?
Thank you for voting!
Related Parts:
Samuel
June 14, 2021
Fridge & freezer not cold, compressor warm but not running, fan running. What could be problem & what parts to repair.
For model number 10650023211
Hi Samuel, thank you for your question. If both the refrigerator and freezer sections are too warm, there are some parts that you will need to check to see which one is causing the issue. The part that fixes the issue the majority of the time is bi-metal defrost thermostat. From our website, the defrost thermostat is a safety thermostat in series with the defrost heater and is used to terminate the defrost cycle when the evaporator reaches a specific temperature, usually rated at 38° to 47° Fahrenheit. If the thermostat is defective and remains open circuit, then the defrost heater will not be energized and no defrosting will take place. You will need to test the part with a multimeter. Set your multi-meter to the Rx1 setting. Place each of the probes on a thermostat wire. When your thermostat is cold, it should produce a reading of zero on your multi-meter. If it is warm (anywhere from forty to ninety degrees Fahrenheit), then this test should produce a reading of infinity. If it does not, you will need to replace it. If this is not the issue, you will need to check the compressor start relay, the evaporator fan motor, the capacitor and the condenser fan motor. We hope this helps!
Was this helpful?
Thank you for voting!
Related Parts:
- < Prev
- 1
- 2
- 3
- Next >
Common Symptoms of the 10650023211
[Viewing 21 of 21]Door won’t open or close
Fixed by
these parts
these parts
Show All
Fridge too warm
Fixed by
these parts
these parts
Show All
Noisy
Fixed by
these parts
these parts
Show All
Ice maker won’t dispense ice
Fixed by
these parts
these parts
Show All
Light not working
Fixed by
these parts
these parts
Show All
Ice maker not making ice
Fixed by
these parts
these parts
Show All
Clicking sound
Fixed by
these parts
these parts
Show All
Leaking
Fixed by
these parts
these parts
Show All
Freezer not defrosting
Fixed by
these parts
these parts
Show All
Fridge and Freezer are too warm
Fixed by
these parts
these parts
Show All
Freezer section too warm
Fixed by
these parts
these parts
Show All
Will Not Start
Fixed by
these parts
these parts
Show All
Not dispensing water
Fixed by
these parts
these parts
Show All
Frost buildup
Fixed by
these parts
these parts
Show All
Fridge too cold
Fixed by
these parts
these parts
Show All
Door Sweating
Fixed by
these parts
these parts
Show All
Freezer too cold
Fixed by
these parts
these parts
Show All
Too warm
Fixed by
these parts
these parts
Show All
Ice maker dispenses too much ice
Fixed by
these parts
these parts
Show All
Ice maker dispenses too little ice
Fixed by
these parts
these parts
Show All
Fridge runs too long
Fixed by
these parts
these parts
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Plastic bits dispensed from Ice Dispenser in Door
Removed Ice bin from Fridge
Removed all bolts on bin with nut driver...about six
Removed housing...be careful with spring on crusher/cube control rod
Removed C clamp on end of auger with small slotted screw driver and needle nose pliers.
Removed plastic nut on end of auger shaft
Removed Ice crusher jaws and laid them out in the correct order
Removed Ice propeller and installed new part
Put back together in opposite order
Easy
Removed all bolts on bin with nut driver...about six
Removed housing...be careful with spring on crusher/cube control rod
Removed C clamp on end of auger with small slotted screw driver and needle nose pliers.
Removed plastic nut on end of auger shaft
Removed Ice crusher jaws and laid them out in the correct order
Removed Ice propeller and installed new part
Put back together in opposite order
Easy
Parts Used:
-
john from seaford, VA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set
203 of 241 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge was getting too warm, ice buildup on coils.
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.
Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.
Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket
Steps:
1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.
2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.
3: Un-clip the bi-metal strip from the evaporator coils.
4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.
5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.
6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.
7: Do the same for the ends of the wires on the (new) bi-metal strip.
8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.
9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.
10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.
11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.
12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).
13: Replace the panel that covers the coils.
14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.
Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket
Steps:
1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.
2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.
3: Un-clip the bi-metal strip from the evaporator coils.
4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.
5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.
6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.
7: Do the same for the ends of the wires on the (new) bi-metal strip.
8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.
9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.
10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.
11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.
12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).
13: Replace the panel that covers the coils.
14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Parts Used:
-
Cathy from Winter Park, FL
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
155 of 181 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
evaporator fan stopped working
1) removed the face plate that runs 3/4 way up the back of the freezer side. a total of 8 screws. (6")
2) disconnected the three electrical connections.(30sec)
3) removed the fan of the the old evaporator fan motor (5sec)
3) removed the fan motor (1")
4) put in the new fan motor (1")
5) put on the old fan on the new fan motor(5sec)
6) reconnected the three electrical connections (30sec)
7) replaced the face plate on the back of the freezer (6")
Had re-frozen meat within 1 hour.
2) disconnected the three electrical connections.(30sec)
3) removed the fan of the the old evaporator fan motor (5sec)
3) removed the fan motor (1")
4) put in the new fan motor (1")
5) put on the old fan on the new fan motor(5sec)
6) reconnected the three electrical connections (30sec)
7) replaced the face plate on the back of the freezer (6")
Had re-frozen meat within 1 hour.
Parts Used:
-
Antoni from vail, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
95 of 104 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!