Ignitor – Part Number: WP4392003
Ignitor
PartSelect #: PS11742507
Manufacturer #: WP4392003
This igniter can only be used in place of round style igniters. This part ignites the gas within the dryer.
$55.99
  Special Order
Refrigerator Thermostat Sensor Barrier – Part Number: WP2196003
Refrigerator Thermostat Sensor Barrier
PartSelect #: PS11739216
Manufacturer #: WP2196003
The thermostat sensor barrier covers and insulates the temperature control thermostat capillary tube.
$13.95
  In Stock
DISCONTINUED – Part Number: 34100
DISCONTINUED
PartSelect #: PS778342
Manufacturer #: 34100
  No Longer Available
Timer – Part Number: Y305020
Timer
PartSelect #: PS1760679
Manufacturer #: Y305020
This dryer timer is used to control the unit's cycles by regulating the length of time that power is directed to each setting.
  No Longer Available
Main – Part Number: 33938
Main
PartSelect #: PS12277355
Manufacturer #: 33938
  No Longer Available
DISCONTINUED – Part Number: 34063
DISCONTINUED
PartSelect #: PS83829
Manufacturer #: 34063
  No Longer Available
DISCONTINUED – Part Number: 29427
DISCONTINUED
PartSelect #: PS211051
Manufacturer #: 29427
  No Longer Available
SPRING – Part Number: 33745
SPRING
PartSelect #: PS1258830
Manufacturer #: 33745
  No Longer Available
DISCONTINUED – Part Number: 34092
DISCONTINUED
PartSelect #: PS778341
Manufacturer #: 34092
  No Longer Available
DISCONTINUED – Part Number: 34175
DISCONTINUED
PartSelect #: PS778344
Manufacturer #: 34175
  No Longer Available
DISCONTINUED – Part Number: 34915
DISCONTINUED
PartSelect #: PS778370
Manufacturer #: 34915
  No Longer Available
HANDLE – Part Number: 35008
HANDLE
PartSelect #: PS1255619
Manufacturer #: 35008
  No Longer Available
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The timer would not shut off the dryer.
I Unplugged the dryer from the electrical outlet. Then took off the top panel. Then removed the nut holding on the selector dial, and removed the selector dial. I then removed the two screws holding the timer to the panel. Then I removed and installed each electrical connector from the defective timer, installing it on the new timer. Then reverse procedure to assemble the dryer.
The best part of the whole experience was the quick service I received from PartSelect. Thank you very much.
Val
Parts Used:
Timer
  • Val from La Habra, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no ignition, igniter not glowing, electricity good
easy even for an old man. Simply removed igniter bracket inside access door on the front and installed new part. Flex drive nut driver and 1/4" socket was all that was needed. Saved me a lot of money and time without the 25 year old dryer.
Parts Used:
Ignitor
  • gary from MANASQUAN, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!