01931-0 Briggs and Stratton Generator - Overview
Sections of the 01931-0
[Viewing 1 of 1]Keep searches simple, eg. "belt" or "pump".
Solenoid, Gas Fuel
PartSelect #: PS8909253
Manufacturer #: 194683GS
This is a genuine Briggs & Stratton replacement part. The gas fuel solenoid is designed by the manufacturer for use in generators. This part is made primarily of metal, and is used to control the fl...
$539.95
Special Order
Switch, Set Exercise
PartSelect #: PS9160620
Manufacturer #: 87799GS
The set exercise switch attaches to the hour meter. This is a genuine Briggs & Stratton part sourced directly from the manufacturer for use in generators. This part is available as an individual repla...
$9.95
Special Order
Key, Lock
PartSelect #: PS9184142
Manufacturer #: B5053GS
This is an authentic manufacturer-sourced part which is specially made for Briggs and Stratton generators. It is an identical replacement for a missing or a faulty lock key that was included with a ne...
$12.95
Special Order
Regulator, Fuel
PartSelect #: PS11828149
Manufacturer #: 316866GS
This is an OEM part sourced directly from the manufacturer. The fuel regulator is commonly found in Briggs & Stratton generators. This part is made of metal, with high-quality plastic fittings, and ...
$550.95
Special Order
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
No voltage on secondary side of transformer. Confirmed with meter that transformer windings had infinite resistance.
1. Turn the generator selector switch to "OFF"
2. Remove the 240 volt fuses in the automatic transfer switch to remove power to the transformer.
3. Remove the outside cover from the front of the generator, on the motor end.
4. Remove the 3 screws from the panel covering the controls.
5. Label or make note of which terminals the 4 wires on the transformer go to and disconnect from transformer.
6. Using 9/32 nutdriver, remove the two transformer mounting nuts and lock washers.
7. Remove old transformer from studs and install new one. Reinstall nuts and lock washers.
8. Reconnect the 4 transformer wires.
9. Reinstall the control panel cover and the generator housing end cover.
10. Reinstall the fuses in the automatic transfer switch.
11. Put the generator selector switch back in "Automatic"
2. Remove the 240 volt fuses in the automatic transfer switch to remove power to the transformer.
3. Remove the outside cover from the front of the generator, on the motor end.
4. Remove the 3 screws from the panel covering the controls.
5. Label or make note of which terminals the 4 wires on the transformer go to and disconnect from transformer.
6. Using 9/32 nutdriver, remove the two transformer mounting nuts and lock washers.
7. Remove old transformer from studs and install new one. Reinstall nuts and lock washers.
8. Reconnect the 4 transformer wires.
9. Reinstall the control panel cover and the generator housing end cover.
10. Reinstall the fuses in the automatic transfer switch.
11. Put the generator selector switch back in "Automatic"
Parts Used:
-
Laron from GRAND RAPIDS, MI
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wouldn’t start.
I installed a new solenoid starter. Took me a total of 20 minutes. Started right up.