This part is a replacement screw for your oven. It is made of black metal and is sold individually. This screw is approximately 1/4 inch in diameter and about 1/2 inch in length. It is designed to con...
It wasn’t the magnetron. It wasn’t the diode. It wasn’t just the fuse. It was the High Voltage Capacitor (HVC). You know, the very thing they warn you about when opening the microwave. Just remember to discharge it using needle-nose pliers before probing around to find the problem. I also suggest you invest in a multimeter so as not to waste hundreds of dollars like I did; that way you can go straight to the real problem instead of replacing symptoms. If you replace the HVC, you will also want to replace the two fuses right in front of it. Also, there is a wiring diagram and a troubleshooting flowchart tucked behind the front console near the top. It is extremely useful!