Ask our experts a question about this model and we'll get back to you as soon as possible!
1 question answered by our experts.
< Prev
1
Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Tess
January 28, 2023
I just need to know the dimensions on this Stove top so I can be exact when ordering a new one Thanks so much !
For model number FEC30C4ACD
Hello Tess, Thank you for your inquiry. We show the measurements of this unit as 30 inches by 3 inches by 21 1/2 with an under counter clearance of 5 inches. We hope this helps you.
1 person found this helpful.
Was this helpful?
Thank you for voting!
< Prev
1
Next >
✖
Ask a Question
Ask our experts a question on this model and we'll respond as soon as we can.
First I unplugged the stove.Removed the upper control panel back (10 phillips screws). Removed the plastic dial( pulls straight off). Removed the 2 screws behind the dial that is holding the switch in the control panel. Took one wire at a time off the old switch and put them on the new switch according to each electrical spade marking. L1, L2, H1, H2 and P. Installed the new switch in the control panel securing it with the 2 screws. Installed the dial, installed the upper back panel using the old screws. Plugged the stove back in and tested it. Note: My new switches shaft was 1/8 of an inch longer so it does put the dial a little further away from the control panel. Wife says: It's OK, don't worry about it.
was more of a job of splicing wires together than anything else. Loved the heat shrink electrical tubing to put over the wires for insulation. used a hair dryer. must buy more of that amazing stuff