Part Location Diagram of W11227239 Whirlpool Defrost Control Board
See part 12 in the diagram
( Grid squares measure 1x1 inch )
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

customerservice@partselect.ca

Defrost Control Board

$511.16
  In Stock

Get this part fast! Average delivery time for in-stock parts via standard shipping: 1.8 days.

PartSelect Number PS12349580
Manufacturer Part Number W11227239
Manufactured by Whirlpool
Product Description

Defrost Control Board Specifications

This board does not come with the protective white outer casing.
How Buying OEM Parts Can Save You Time and Money

How Buying OEM Parts Can Save You Time and Money

Troubleshooting
This part fixes the following symptoms:
Fridge too warm | Will Not Start | Freezer section too warm
This part works with the following products:
Refrigerator.
This part works with the following products:
Maytag, Amana, Kenmore, Crosley.
Part# W11227239 replaces these:
AP6329557, 12002495, 67003375, 67004704, WP67004704
Back to Top
Customer Repair Stories
 Average Repair Rating: 3.1 / 5.0, 4 reviews. What's this?
  • 1
Sort by:
Sorry, we couldn't find any existing installation instruction that matched.
no cold air
Installed new parts worked great and most important wife was happy again
Other Parts Used:
Refrigerator Vertical Mullion Rail - Black Run Capacitor Relay Overload
  • raymond from dallas, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
33 of 67 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator was not getting cold
For the defrost control board, it is a really easy replacement on my model Maytag refrigerator, all you have to do locate the freezer/refrig, cooling controls in the main part of frig and remove the control knobs by pulling them of by hand, for the cover use 1/4 socket with a socket wrench or socket screw driver to remove the cover, after that you will see a panel cover that you have to unclip by hand and that is where your control board is located and at this point it's just plug and play. just reassemble in reverse order. I changed my overload relaywith start capaciter out also when I changed my defrost control board. To change the relay out, first remove the lower panel on the rear base of the frig. and this is where you will find the relay pluged into the round black compressor, simply unplug the old and plug the new in, it's just that simple!
Other Parts Used:
Compressor Start Device and Capacitor
  • Eugene from Bakersfield, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
27 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge was not cooling and staying around 50 degrees. Freezer was cooling normally.
Looked on web to see problems with same model. Recieved new board, unplugged fridge,took off cover inside fridge top left,took old board out, unplugged wires from old board and plugged new board in, installed cover and plugged fridge into wall outlet.
Other Parts Used:
  • brandt from sycamore, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge side not cold when freezer is blasting cold
I knew it was either the thermostat or defrost control board. Checked resistance with multimeter across the thermostat and heater element. Both check out ok so I replaced the board and all is good. Board on my model was in the controls panel.
Other Parts Used:
  • Daniel from Bellflower, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
  • 1
Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

2 questions answered by our experts.
  • 1
Sort by:
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Paulette
June 7, 2019
If only lights come on in refrigerator and no prior symptoms of not cooling properly or clicking noise. Just stopped doing anything all at once with only lights now working, what part would most likely need replaced? Compressor, start capacitor or electric control board?Thanks, paulette
For model number MSD2352KES
PartSelect logo
Hi Paulette, thank you for your question. When you are having temperature problems in your fridge, there are a few parts that could cause the issue. You can use a multi meter to test most of the parts. Make sure you cut power to your appliance before doing any repairs or tests. First you should test your defrost thermostat. Place the thermostat in ice cold water for 2-3 minutes after removing it from your appliance. It should be reading 0 ohms to be working correctly. Another part to check would be your defrost heater. Remove it from the appliance. It should be reading anywhere between 0 - 50 ohms to be working. You could check your temperature sensor. To find the correct reading for this part you will have to refer to your tech sheet that comes with your appliance. You can usually find this tech sheet behind the bottom grille of your fridge on either the right or left side. These are the most common parts that cause this issue in your appliance. So it is suggested you check them first. I hope that helps. Good luck with your repair.

3 people found this helpful.

Was this helpful?
Thank you for voting!
Karl
December 26, 2022
with the cube Ice light on and putting a glass in to get ice, the refrig makes a loud noise that comes from the control board area and will continue makeing the noise until you open the freezer door and the noise will stop but no ice comes out the chute, and the auger drive turns when you check you try it with the ice container empty or out any help
For model number MSD2351HEB
PartSelect logo
Hi Karl, Thank you for your question. If you are switching from crushed to cubed ice, it is normal to get a small amount of crushed ice at first. When you switch to cubed ice, a lever behind the ice bucket opens a flap to allow cubed ice to be dispensed. If an ice cube gets caught behind the ice bucket, it can prevent the lever from working. You will need to remove the ice bucket and remove any ice that may have fallen behind it. If there are no ice cubes behind the bucket, try dispensing ice with the bucket removed. Shut the refrigerator door and press the ice dispenser. You are doing this to see if you hear a loud snapping noise. If there is no snapping noise, service will be needed. If you hear a snapping noise, reinsert the bucket and try cubed ice again. If cubed ice is not dispensed, then check the ice bucket to see if the ice in it has frozen together. If it has frozen together, dump it out and clean the bucket. Reinsert the bucket and try the dispenser again. The noise may also be caused by the auger motor when it tries to push the ice out. You will need to inspect it to make sure it is working properly. If you have any questions, please let us know. We are open 7 days a week. We look forward to hearing from you!

Was this helpful?
Thank you for voting!
  • 1
;
Related Parts
Model Cross Reference
This part works with the following models:
PartSelect Number: PS12349580
Manufacturer Part Number: W11227239
Brand
Model Number
Description
Kenmore
59652672201
Refrigerator
Kenmore
59652672202
Refrigerator
Kenmore
59652673201
Refrigerator
Kenmore
59652673202
Refrigerator
Kenmore
59652674201
Refrigerator
Kenmore
59652674202
Refrigerator
Kenmore
59652679201
Refrigerator
Kenmore
59652679202
Refrigerator
Kenmore
59653462301
Refrigerator
Kenmore
59653462302
Refrigerator
Kenmore
59653463301
Refrigerator
Kenmore
59653463302
Refrigerator
Kenmore
59653464301
Refrigerator
Kenmore
59653464302
Refrigerator
Kenmore
59653469301
Refrigerator
Kenmore
59653469302
Refrigerator
Kenmore
59672252202
Refrigerator
Kenmore
59672253202
Refrigerator
Kenmore
59672254202
Refrigerator
Kenmore
59672259202
Refrigerator
Kenmore
59672282202
Refrigerator
Kenmore
59672283202
Refrigerator
Kenmore
59672284202
Refrigerator
Kenmore
59672289202
Refrigerator
Kenmore
59673502201
Refrigerator
Kenmore
59673502202
Refrigerator
Kenmore
59673502203
Refrigerator - KENMORE REFRIGERATOR
Kenmore
59673502300
Refrigerator
Kenmore
59673503201
Refrigerator
Kenmore
59673503202
Refrigerator
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

Contact Customer Service