Troubleshooting
This part fixes the following symptoms:
Won’t turn on
This part works with the following products:
Microwave.
This part works with the following products:
Frigidaire, Kenmore, Uni, Electrolux.
Part# 5304509459 replaces these:
AP6230614, 5304464098
Back to Top
Customer Reviews
Average Rating:
★★★★★
★★★★★
1 Review
5.0
Filter By Rating:
  • 5 Stars
    1
  • 4 Stars
    0
  • 3 Stars
    0
  • 2 Stars
    0
  • 1 Star
    0
  • 1
Sort by:
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
  • 1
Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

14 questions answered by our experts.
  • 1
  • 2
Sort by:
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Jeff
February 12, 2019
I have blown 2 fuses recently when my son has opened the microwave door before the time is up. For example, still 5 seconds left - he opens the door to get his food, and the fuse blows. In researching online this sounds like a faulty door switch - does this sound right? (i realize there's no way to be sure so a best guess is fine here). Thanks!
For model number FGMV175QFA
PartSelect logo
Hello Jeff, Thank you for the question. Yes, the most common part replaced for this issue is the door switches. You can test for continuity with a multi meter as well before replacing the switch. Thank you for your inquiry, good luck with this repair!

30 people found this helpful.

Was this helpful?
Thank you for voting!
Gregory
December 7, 2019
My microwave oven starts when the door is shut, it will shut off when the bottom right side of the door is pushed in. It sounds like when i push on the door a switch clicks inside the control panel area. Which switch controls this feature? It will start anytime the door is opened and shut whether microwave is in use or not. I don't believe the heating function turns on when this happens. Thanks!!! greg
For model number fmv152kma
PartSelect logo
Hello Gregory and thanks for writing. It sounds like a faulty Door switch PS12071302 check and replace if needed. We hope this helps. Please contact us anytime.

11 people found this helpful.

Was this helpful?
Thank you for voting!
Jake
March 8, 2019
Is this the middle switch of the three?
For model number FFMV164LSA
PartSelect logo
Hello Jake, thank you for your question. Yes, this is the middle switch, Part Number: PS12071302. Good luck with your repair!

9 people found this helpful.

Was this helpful?
Thank you for voting!
Shirley
February 12, 2020
Our microwave blows the breaker when the door is closed. If we reset the breaker with the door open, microwave turns on, shut the door, and the breaker blows. Could this be the center door switch?
For model number Cgmv175qfa
PartSelect logo
Hi Shirley, thank you for your question. It could be yes. There are a few parts that could cause this issue however. You may also want to check your two other door switches and your fuse as well. Good luck with your repair.

4 people found this helpful.

Was this helpful?
Thank you for voting!
Tom
July 5, 2021
Tripping breaker at turn on. Can you tell me part # for door switches. Also I would like the fuse number. Thank you. Also, having trouble finding the screws to take out to access fuse and switches.
For model number FGMV176NTDB
PartSelect logo
Hello Tom, Thank you for contacting us. We have researched the model you have provided and have found the part you are looking for is Part #: PS12071302 and Part #: PS12071303 (two required) for the Door Switches. The Fuse is PartSelect Number PS12071294, To access the Fuse you will need to remove the appliance from the mount and remove the screws at the back of the appliance to remove the casing of the appliance. We hope this helps!

2 people found this helpful.

Was this helpful?
Thank you for voting!
Related Parts:
Josh
November 8, 2021
While running the microwave if I open it before time expires it will trip the breaker. There are 3 switches on the door, I was wonder if you’ve heard of this problem or if this is the right switch for that problem?
For model number FGMV176NTF
PartSelect logo
Hello Josh, thank you for your question. You can test your door switches with a multimeter. First, unplug your microwave. Some door switches have only two metal prongs extending from the body, while others have three. Those with three terminals will have a common (COM) terminal, a normally closed (N.C.) terminal, and a normally open (N.O.) terminal. Those switches with only two terminals will have either a common terminal and a normally open terminal, or a common terminal and a normally closed terminal. We are providing directions for testing a door switch with three terminals. If you are dealing with a door switch that has only two terminals, ignore the part of this test that does not apply to you. Using caution, remove all wiring harness leads from the switch's terminals. Use your ohmmeter to test your switch for continuity. Begin by setting your ohmmeter to measure resistance at a scale of Rx1. If you are using an analog meter, touch the metal tips of the test leads together and zero your ohmmeter by adjusting the thumbwheel in the front of the meter until the needle reads '0' on the scale. Touch one meter lead to the COM terminal and the other lead to the N.O. terminal. Do not push in on the actuator. Your meter should give a reading of infinity, meaning the circuit is open, and there is no continuity. Without moving the meter's leads, press down on the actuator until you hear a 'click'. With the 'click' of the actuator, the meter should produce a resistance reading of zero ohms. This means the circuit is closed and continuity is present. (switches with only two terminals do not 'click' when actuated) Keep the meter lead that is touching the COM terminal in place, but move the other meter lead from the N.O. terminal to the N.C. terminal. You should receive a reading of infinity when you push in on the switch's actuator. When the actuator is released, you should receive a resistance reading of zero ohms. Now, set your ohmmeter to its highest resistance scale and touch one meter lead to the N.O. terminal and the other meter lead to the N.C. terminal. The resistance reading between these two leads should be infinite. Finally, take a resistance reading from both the N.C. terminal and the N.O. terminal to any metal mounting hardware that is a part of the switch assembly. You should receive a normal reading of infinity. Any readings that differ from the ones presented here are indicative of a defective door switch that will need to be replaced. Door switch part number PS12071302 and Switch part number PS12071303. We hope this helps.

2 people found this helpful.

Was this helpful?
Thank you for voting!
Related Parts:
Keith
June 7, 2023
When trying to start the microwave, the error reads close door. if we put a Q Tip or a small finger into the door slot to give a slight movement where the three switches are, it rectifies the problem for the moment. Eventually the error returns and we repeat the process. I'd like to know which of the three switches controls the close door circuit safety net. The middle switch is a closed cct until activated when door closes to open cct. The two on each side of this switch are opened cct until the door closes then the switch closes the cct.
For model number E130BM6CPSA
PartSelect logo
Hi Keith, thank you for reaching out. The door interlock switch, part number PS12071302, prevents the microwave from starting when the door is open. You need to check the door interlock to fix this issue. We hope this helps!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Allan
March 14, 2024
I understand there are 3 door switches. Which one do I replace if breaker is tripped when I close the door?
For model number CGMV175QFA
PartSelect logo
Hello Allan, thank you for a very interesting question. Your model comes with 3 door switches. Two door switches have the same part number PS12071303. The third door switch is part number PS12071302. You may need to check them all for continuity and replace the faulty one accordingly. We hope this helps.

1 person found this helpful.

Was this helpful?
Thank you for voting!
Related Parts:
Daniel
September 27, 2023
my microwave will trip the breaker if i stop it while working.
For model number 790 80333310
PartSelect logo
Hi Daniel, thank you for reaching out. Based on our research, the issue is most probably because of the door switch, part number PS12071302. We would suggest replacing the door switch to fix the issue. We hope this solves your problem!

Was this helpful?
Thank you for voting!
Robert
April 19, 2022
When I turn on the microwave the circuit breaker trips and the microwave cuts off. I tried a heavy-duty extension cord from an outlet and plugged in the microwave and the microwave cut off. Can this be caused by a bad door switch and if so which one? How many door switches are there in this microwave? If one is bad does that mean the rest should be replaced also? What is the number of the part number on the diagram of the microwave?
For model number FGMV176NTF
PartSelect logo
Hello Robert, thank you for your question. There are 2 of one type of switch and one of another. You will need to test all three. The part number of the switch of which there are two is PS12071303(NLA) and the other is PS12071302. If you need help placing an order, customer service is open 7 days a week. Please feel free to give us a call. We look forward to hearing from you.

Was this helpful?
Thank you for voting!
Related Parts:
  • 1
  • 2
Related Parts
Model Cross Reference
This part works with the following models:
PartSelect Number: PS12071302
Manufacturer Part Number: 5304509459
Brand
Model Number
Description
Kenmore
79080322310
Microwave - MICROWAVE OVEN
Kenmore
79080323310
Microwave - MICROWAVE OVEN
Kenmore
79080329310
Microwave - MICROWAVE OVEN
Kenmore
79080332310
Microwave - MICROWAVE/HOOD COMBO
Kenmore
79080333310
Microwave - MICROWAVE/HOOD COMBO
Kenmore
79080339310
Microwave - MICROWAVE/HOOD COMBO
Kenmore
79080342310
Microwave - MICROWAVE OVEN
Kenmore
79080343310
Microwave - MICROWAVE OVEN
Kenmore
79080349310
Microwave - MICROWAVE OVEN
Kenmore
79080352310
Microwave - MICROWAVE OVEN
Kenmore
79080353310
Microwave - MICROWAVE OVEN
Kenmore
79080354310
Microwave - MICROWAVE OVEN
Kenmore
79080359310
Microwave - MICROWAVE OVEN
Kenmore
79080362310
Microwave - Kenmore Microwave Model 790.80362310 (79080362310, 790 80362310) Parts
Kenmore
79080363310
Microwave - Kenmore Microwave Model 790.80363310 (79080363310, 790 80363310) Parts
Kenmore
79089393510
Microwave - MICROWAVE OVEN
Frigidaire
CFMV152CLBA
Microwave
Frigidaire
CFMV152CLWA
Microwave
Frigidaire
CFMV152KBA
Microwave
Frigidaire
CFMV152KMA
Microwave
Frigidaire
CFMV152KQA
Microwave
Frigidaire
CFMV152KSA
Microwave
Frigidaire
CFMV152KWA
Microwave
Frigidaire
CFMV154CLSA
Microwave
Frigidaire
CFMV157GBA
Microwave - Hood Combo
Frigidaire
CFMV157GCA
Microwave - Hood Combo
Frigidaire
CFMV157GMA
Microwave - Hood Combo
Frigidaire
CFMV157GQA
Microwave - Hood Combo
Frigidaire
CFMV157GSA
Microwave - Hood Combo
Frigidaire
CFMV162LBA
Microwave
Customer Service Representative

Get in touch, we're here to help!

Daily 8am - 9pm EST

Contact Customer Service